− | == DTI Meeting Minutes | April | + | == DTI Meeting Minutes | April 26, 2006 == |
− | <br /> Present: | + | <br /> Present: Doug, Marc, Katharina, Sylvain, Kang Uk, Gordon, CF, Marek, Gudrun |
− | <br /> | + | <br /> |
− | * | + | * Slicer |
− | * | + | ** Slicer26 should be able to read NRRD DWIs now |
+ | ** doDTI gives you mean FA, would be nice to display this in Slicer somewhere | ||
− | <br /> | + | <br /> |
− | * | + | * New protocol: scanning today? |
− | * | + | ** required that a licensed MD approve every scan |
+ | ** sequence will be DICOM files, probably same format as before, same procedure for downloading | ||
+ | ** Marek meeting with Nan-Quei at 1:30 today at the SPL to talk about the protocol | ||
+ | ** Will try multiple scans varying b-value and number of directions | ||
+ | *** Will try 750 and 1000 with minimum of 32 directions; also try 50 directions | ||
− | <br /> | + | <br /> |
− | * | + | * Anterior Commissure |
+ | ** would be nice to have an extra scalar map with orientation overlayed with the output of this method | ||
+ | ** Gordon will finish creating these maps and send to Sylvain | ||
− | <br /> | + | <br /> |
− | * | + | * Cingulum Bundle histograms of FA/Mode |
+ | ** note that people tend to overestimate how linear the ROI will be.. mostly orthotropic | ||
+ | ** now that we know that anisotropy is a bi-variate quantity, still need to answer the question about how to do statistics on this; non-parametric tests? | ||
+ | ** would be helpful to have comparison of different white matter ROIs, plotted in this space | ||
+ | *** Corpus callosum, cingulum bundle, STG white matter, STG gray matter, CSF; these ROIs will be sent to Gordon | ||
+ | |||
+ | <br /> | ||
+ | |||
+ | * Kang Uk - problem with tensor coregistration? | ||
+ | ** script was updated by Mattan in slicer-nightly, but still doesn't seem to be working | ||
+ | ** will try a basic co-registration of two tensor sets in the same direction |
Revision as of 13:19, 18 December 2006
Home < DBP:Harvard:Software:Minutes:4DTI Meeting Minutes | April 26, 2006
Present: Doug, Marc, Katharina, Sylvain, Kang Uk, Gordon, CF, Marek, Gudrun
- Slicer
- Slicer26 should be able to read NRRD DWIs now
- doDTI gives you mean FA, would be nice to display this in Slicer somewhere
- New protocol: scanning today?
- required that a licensed MD approve every scan
- sequence will be DICOM files, probably same format as before, same procedure for downloading
- Marek meeting with Nan-Quei at 1:30 today at the SPL to talk about the protocol
- Will try multiple scans varying b-value and number of directions
- Will try 750 and 1000 with minimum of 32 directions; also try 50 directions
- Anterior Commissure
- would be nice to have an extra scalar map with orientation overlayed with the output of this method
- Gordon will finish creating these maps and send to Sylvain
- Cingulum Bundle histograms of FA/Mode
- note that people tend to overestimate how linear the ROI will be.. mostly orthotropic
- now that we know that anisotropy is a bi-variate quantity, still need to answer the question about how to do statistics on this; non-parametric tests?
- would be helpful to have comparison of different white matter ROIs, plotted in this space
- Corpus callosum, cingulum bundle, STG white matter, STG gray matter, CSF; these ROIs will be sent to Gordon
- Kang Uk - problem with tensor coregistration?
- script was updated by Mattan in slicer-nightly, but still doesn't seem to be working
- will try a basic co-registration of two tensor sets in the same direction