Revision as of 21:27, 30 November 2010
Home < OpenIGTLink < ProtocolV2 < Type < PointContents
Summary
The POINT message type is designed to transfer information about fiducials, which are often used in surgical planning and navigation in the image-guided therapy.
Message Types
POINT
Data | Type | Description |
SENSOR_1 | ||
Name | char[64] | Name or description of the point |
Group name | char[32] | Can be "Labeled Point", "Landmark", "Fiducal", ... |
R,G,B,A | 8 bit unsigned | Color in RGBA |
X,Y,Z | 32 bit float | Coordinate of the point in millimeter |
Diameter | 32 bit float | Diameter of the point in millimeter. Diameter can be 0. |
Owner image | char[20] | Id of the owner image/sliceset. Points from different slicesets can be sent if slicesets are fused. |
... | ||
SENSOR_N | ||
Name | char[64] | Name or description of the point |
Group name | char[32] | Can be "Labeled Point", "Landmark", "Fiducal", ... |
R,G,B,A | 8 bit unsigned | Color in RGBA |
X,Y,Z | 32 bit float | Coordinate of the point in millimeter. |
Diameter | 32 bit float | Diameter of the point in millimeter. Diameter can be 0. |
Owner image | char[20] | Id of the owner image/sliceset. Points from different slicesets can be sent if slicesets are fused. |
GET_POINT
GET_POINT is used to query for meta data of label data. If the DEVICE_NAME field in the header is empty, a list of all available label data is returned.
Data | Type | Description |
STT_POINT
N / A
STP_POINT
N/A
RTS_POINT
N/A
Implementations
IMGMETA message type is implemented in the following source code.
Contributors