Difference between revisions of "Non-rigid MR-CT Image Registration"
(11 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | = Non-rigid | + | = Non-rigid Registration of Pre-procedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer Tutorial= |
==Overview== | ==Overview== | ||
Line 12: | Line 12: | ||
*A multi-modality non-rigid registration method can enhance visualization of tumor margins and location during the planning, targeting, and monitoring phases of CT imaging-guided cryoablation procedure. | *A multi-modality non-rigid registration method can enhance visualization of tumor margins and location during the planning, targeting, and monitoring phases of CT imaging-guided cryoablation procedure. | ||
− | [[Image: | + | [[Image:registrationStrategy.png |REGISTRATION STRATEGY / ROADMAP: |500px|thumb|right]] |
=== Tutorial Topics / Targets === | === Tutorial Topics / Targets === | ||
* Slicer Modules Used: | * Slicer Modules Used: | ||
− | ** | + | ** N4ITKBiasField Correction |
** Editor | ** Editor | ||
** BRAINSFitIGT Registration | ** BRAINSFitIGT Registration | ||
Line 27: | Line 27: | ||
** Planning and Intra-operative CT with cryo-probe | ** Planning and Intra-operative CT with cryo-probe | ||
− | + | ||
Line 37: | Line 37: | ||
** MRI Bias Field Intensity Correction | ** MRI Bias Field Intensity Correction | ||
* Registration | * Registration | ||
− | ** MRI-CT non-rigid registration | + | ** MRI-CT(#1) non-rigid registration |
− | ** CT-CT affine registration | + | ** CT(#1)-CT(#2) affine registration |
** Resampling & Fusion | ** Resampling & Fusion | ||
==Tutorials== | ==Tutorials== | ||
− | '''Non-rigid | + | '''Non-rigid Registration of Pre-procedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer Tutorial''' [[Media:Non-rigid_Registration_of_Pre-procedural_MRI_and_Intra-procedural_CT_for_CT-guided_Cryoablation_Therapy_of_Liver_Cancer_TutorialContestSummer2011.ppt| [ppt]]][[Media:Non-rigid_Registration_of_Pre-procedural_MRI_and_Intra-procedural_CT_for_CT-guided_Cryoablation_Therapy_of_Liver_Cancer_TutorialContestSummer2011.pdf| [pdf]]] |
==Tutorial materials== | ==Tutorial materials== | ||
Line 50: | Line 50: | ||
'''Material data''': | '''Material data''': | ||
*[[Media:Non-rigid_MR_CT_Image_RegistrationTutorialData_TutorialContestSummer2011.tar.gz| Non-rigid_MR_CT_Image_RegistrationTutorialData_TutorialContestSummer2011.tar.gz ]] | *[[Media:Non-rigid_MR_CT_Image_RegistrationTutorialData_TutorialContestSummer2011.tar.gz| Non-rigid_MR_CT_Image_RegistrationTutorialData_TutorialContestSummer2011.tar.gz ]] | ||
+ | |||
+ | |||
+ | ==Reference== | ||
+ | This method is based on the registration workflow originally developed for prostate MRI registration as follows. | ||
+ | |||
+ | A. Fedorov, K. Tuncali, F. Fennessy, J. Tokuda, N. Hata, S.W. Wells, R. Kikinis, and C.M. Tempany. Hierarchical Image Registration for Improved Sampling during 3T MRI-guided Transperineal Targeted Prostate Biopsy, ISMRM 2011 | ||
==People== | ==People== |
Latest revision as of 21:52, 22 June 2011
Home < Non-rigid MR-CT Image RegistrationNon-rigid Registration of Pre-procedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer Tutorial
Overview
This tutorial demonstrates how to perform a pre-operated contrast enhanced MR image to intra-procedure CT image non-rigid registration. The case study is CT-guided liver tumor cryoablation.
Clinical significants
- Non-rigid registrations desirable to compensate for liver deformation caused by patient positioning, respiratory motion, and interventional manipulation.
- A multi-modality non-rigid registration method can enhance visualization of tumor margins and location during the planning, targeting, and monitoring phases of CT imaging-guided cryoablation procedure.
Tutorial Topics / Targets
- Slicer Modules Used:
- N4ITKBiasField Correction
- Editor
- BRAINSFitIGT Registration
- Image Processing Tasks Performed:
- Intensity non-uniformly correction
- Mask generation / segmentation
- Inter-modality non-rigid image registration
- Image Data Used:
- Pre-operative abdominal MR with surface coil, showing liver
- Planning and Intra-operative CT with cryo-probe
Overview
- This tutorial will go through the following steps (in order):
- Preprocessing
- MRI mask generation
- CT mask generation
- MRI Bias Field Intensity Correction
- Registration
- MRI-CT(#1) non-rigid registration
- CT(#1)-CT(#2) affine registration
- Resampling & Fusion
Tutorials
Non-rigid Registration of Pre-procedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer Tutorial [ppt] [pdf]
Tutorial materials
Material data:
Reference
This method is based on the registration workflow originally developed for prostate MRI registration as follows.
A. Fedorov, K. Tuncali, F. Fennessy, J. Tokuda, N. Hata, S.W. Wells, R. Kikinis, and C.M. Tempany. Hierarchical Image Registration for Improved Sampling during 3T MRI-guided Transperineal Targeted Prostate Biopsy, ISMRM 2011
People
Atsushi Yamada, Ph.D. (Research Associate, Brigham and Women's Hospital and Harvard Medical School)
Dominik S. Meier, Ph.D. (Assistant Professor, Brigham and Women's Hospital and Harvard Medical School)
Nobuhiko Hata, Ph.D. (Associate Professor, Brigham and Women's Hospital and Harvard Medical School)