Difference between revisions of "Projects:RegistrationLibrary:RegLib C13"
From NAMIC Wiki
Line 41: | Line 41: | ||
# | # | ||
=== Registration Results=== | === Registration Results=== | ||
− | + | This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases. | |
+ | |||
===Download === | ===Download === | ||
*'''[[Media:RegLib_C13_LiverTumor2_DATA.zip|download input image data <small> (Input Data, NRRD images, zip file 28 MB) </small>]]''' | *'''[[Media:RegLib_C13_LiverTumor2_DATA.zip|download input image data <small> (Input Data, NRRD images, zip file 28 MB) </small>]]''' |
Revision as of 21:14, 16 August 2011
Home < Projects:RegistrationLibrary:RegLib C13Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
Slicer Registration Use Case Exampe #13: Liver Tumor Cryoablation #2
Objective / Background
We seek to align the pre-operative CT&MRI with the post-operative CT.
Keywords
MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration
Input Data
- reference/fixed : T1 SPGR , 0.9375 x 0.9375 x 1.4 mm voxel size, axial, RAS orientation.
- moving: T1 SPGR , 0.9375 x 0.9375 x 1.2 mm voxel size, sagittal, RAS orientation.
Methods
Registration Results
This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases.
Download
Discussion: Registration Challenges
- large differences in FOV
- strong differences in image contrast between MRI & CT
- contrast enhancement and pathology and treatment changes cause additional differences in image content
- we have strongly anisotropic voxel sizes with much less through-plane resolution