== Pilot Study on BrainsFit Registration of LA Wall and Pulmonary Veins == | == Pilot Study on BrainsFit Registration of LA Wall and Pulmonary Veins == | ||
− | + | Image registration is clinically useful for the alignment of medical images acquired at different time points (among a wide variety of other uses). For the CARMA Center, image registration of longitudinal DEMRI scans can help localize scar formation, the hallmark of ablation therapy success, or the lack thereof. We have experimented with using the BrainsFit registration framework from Slicer to register patient scans, allowing evaluating of lesion formation and lesion gaps around the PVs, a common ablation location. | |
=== Examples === | === Examples === | ||
Line 19: | Line 19: | ||
| An example of generally good registration of both the LA wall and PVs on a patient's pre- and 3 month post-ablation DEMRI scans (affine and rigid registration via BrainsFit module). | | An example of generally good registration of both the LA wall and PVs on a patient's pre- and 3 month post-ablation DEMRI scans (affine and rigid registration via BrainsFit module). | ||
| An example of the pre- and post-ablation images from the same patient that were registered (affine and rigid) with the BrainsFit module. The registration was good except along the septal surface (arrows). | | An example of the pre- and post-ablation images from the same patient that were registered (affine and rigid) with the BrainsFit module. The registration was good except along the septal surface (arrows). | ||
− | | Affine and rigid registration (BrainsFit module) of the same patient's pre- and post-ablation scans improved the alignment of the PVs, but sufficient overlap of the corresponding PV structures was not achieved. | + | | Affine and rigid registration (BrainsFit module) of the same patient's pre- and post-ablation scans improved the alignment of the PVs, but sufficient overlap of the corresponding PV structures was not achieved (arrows). |
|- | |- | ||
|} | |} |
Revision as of 01:18, 9 November 2011
Home < DBP3:Utah:PV BFRegback to DBP3 home
The CARMA DBP: MRI-based study and treatment of atrial fibrillation
Pilot Study on BrainsFit Registration of LA Wall and Pulmonary Veins
Image registration is clinically useful for the alignment of medical images acquired at different time points (among a wide variety of other uses). For the CARMA Center, image registration of longitudinal DEMRI scans can help localize scar formation, the hallmark of ablation therapy success, or the lack thereof. We have experimented with using the BrainsFit registration framework from Slicer to register patient scans, allowing evaluating of lesion formation and lesion gaps around the PVs, a common ablation location.
Examples
Good LA Wall and PV Registration | Septal Misregistration | PV Misregistration |
---|---|---|
An example of generally good registration of both the LA wall and PVs on a patient's pre- and 3 month post-ablation DEMRI scans (affine and rigid registration via BrainsFit module). | An example of the pre- and post-ablation images from the same patient that were registered (affine and rigid) with the BrainsFit module. The registration was good except along the septal surface (arrows). | Affine and rigid registration (BrainsFit module) of the same patient's pre- and post-ablation scans improved the alignment of the PVs, but sufficient overlap of the corresponding PV structures was not achieved (arrows). |
A short movie showing a linear blend between the septal misregistration images (fades from pre- to post-ablation scans).
A second short clip showing a linear blend between the PV misregistration images above (again, from pre- to post-ablation scans).