This work will be delivered to the NA-MIC Kit as an Extension -- commandline
 
  
 
==References==
 
==References==
 
# Edelsbrunner, H., Harer, J., & Zomorodian, A. (2003). Hierarchical Morse--Smale Complexes for Piecewise Linear 2-Manifolds. Discrete and Computational Geometry, 30(1), 87-107. doi:10.1007/s00454-003-2926-5
 
# Edelsbrunner, H., Harer, J., & Zomorodian, A. (2003). Hierarchical Morse--Smale Complexes for Piecewise Linear 2-Manifolds. Discrete and Computational Geometry, 30(1), 87-107. doi:10.1007/s00454-003-2926-5
 
# Szymczak, A., Stillman, A., Tannenbaum, A., & Mischaikow, K. (2006). Coronary vessel trees from 3D imagery: a topological approach. Medical image analysis, 10(4), 548-59. doi:10.1016/j.media.2006.05.002
 
# Szymczak, A., Stillman, A., Tannenbaum, A., & Mischaikow, K. (2006). Coronary vessel trees from 3D imagery: a topological approach. Medical image analysis, 10(4), 548-59. doi:10.1016/j.media.2006.05.002

Revision as of 18:29, 15 June 2012

Home < 2012 Summer Project Week:RidgeExtractionAtrialWallSegmentation

Background

Catheter ablation has been proposed for treatment of atrial fibrillation arrhythmia. MRI data is used to explore lesion ablation and scarification locations are extracted from MRI image data. In addition, MRI analysis may help to predict if the ablation procedure will help a patient or not. Many of these image analysis tasks are largely based on segmentation of left atrial wall, which is done manually or semi-automatically. Automatic segmentation uses moving contours or surfaces (interfaces) to segment image data by minimizing a predefined energy function. These moving interfaces are highly affected by image data, which can be thought as a force field pushing the interface to features of choice. Thus, the choice of interface attracting image features is critical.

Key Investigators

  • BU: Arie Nakhmani
  • BU and CCC UAB: Allen Tannenbaum

Objective

We are exploring different image features which are appropriate for an automatic segmentation. Our objective is to compare different topological extrema ranking algorithms (including maximum persistence [1,2] and perceptual ridge importance) to provide the most appropriate features, based on expert's manual segmentation.




Approach, Plan

  • Implementing the comparison framework
  • Ellipsoidal MRI transform
  • Local ridge extraction
  • Topological persistence algorithm implementation
  • Comparison of different topological simplification approaches


Progress

We have developed topological simplification methods for removing noisy local maxima. The resulting ridge detection algorithm shows average error less then 2 pixels compared to the manual segmentation.



References

  1. Edelsbrunner, H., Harer, J., & Zomorodian, A. (2003). Hierarchical Morse--Smale Complexes for Piecewise Linear 2-Manifolds. Discrete and Computational Geometry, 30(1), 87-107. doi:10.1007/s00454-003-2926-5
  2. Szymczak, A., Stillman, A., Tannenbaum, A., & Mischaikow, K. (2006). Coronary vessel trees from 3D imagery: a topological approach. Medical image analysis, 10(4), 548-59. doi:10.1016/j.media.2006.05.002