This module implements case-specific registration for cardiac LGE-MRI and CT images.  The input to this module is two image volumes.  The user then selects from a set of presets based on the type of images. Registration parameters are tuned for the cases listed [[DBP3:Utah:RegCases|registration case]].
+
This module implements case-specific registration for cardiac LGE-MRI, MRA and CT images.  The inputs to this module are two image volumes.  Volume one is the fixed volume and volume two is the moving volume. The goal of registration is to find a spatial mapping that will align the moving volume with the fixed volume. The user selects the imaging modalities based on the types of input images. Registration parameters are tuned for the cases listed [[DBP3:Utah:RegCases|registration case]]. The input images that are cropped to the area around the left atrium can be used as well, which would improve the final registration result.
  
 
== Usage ==
 
== Usage ==
Line 24: Line 25:
 
===Examples, Use Cases & Tutorials===
 
===Examples, Use Cases & Tutorials===
  
* This module is meant to be used for cardiac LGE-MRI and CT scans acquired at different time points or across different patients.
+
* This module is meant to be used for cardiac LGE-MRI, MRA and CT scans acquired at different time points or across different patients.
  
 
===Quick Tour of Features and Use===
 
===Quick Tour of Features and Use===
Line 30: Line 31:
 
The following are the inputs and outputs
 
The following are the inputs and outputs
  
* Moving Volume : Select the LGE-MRI image
+
* Volume One (Fixed): Select the LGE-MRI, MRA or CT Image
* Fixed Volume : Select the LGE-MRI Image
+
* Volume Two (Moving): Select the LGE-MRI or MRA image
* Output Volume : The output volume
+
* Output Volume : The registration result
* Registration Type : Type of images (e.g LGE-MRI, MRA, CT, Acute Scar)
+
* Imaging modality: The types of images that are being registered (e.g LGE-MRI, MRA, CT, Acute Scar)
  
 
== More Information ==  
 
== More Information ==  
 +
 +
The details about the advanced registration options can be found at [http://www.slicer.org/slicerWiki/index.php/Modules:RegisterImages-Documentation-3.6].
  
 
===Acknowledgment===
 
===Acknowledgment===
  
 
===References===
 
===References===

Revision as of 17:11, 17 October 2012

Home < DBP3:Utah:SlicerModuleCardiacRegistration

CARMA Cardiac Registration Module

General Information

Module Type & Category

Type: CLI

Category: CARMA

Authors, Collaborators & Contact

  • Alan Morris: CARMA Center, University of Utah
  • Greg Gardner: CARMA Center, University of Utah
  • Salma Bengali: CARMA Center, University of Utah
  • Josh Cates: CARMA Center, University of Utah
  • Rob MacLeod: CARMA Center, University of Utah

Module Description

This module implements case-specific registration for cardiac LGE-MRI, MRA and CT images. The inputs to this module are two image volumes. Volume one is the fixed volume and volume two is the moving volume. The goal of registration is to find a spatial mapping that will align the moving volume with the fixed volume. The user selects the imaging modalities based on the types of input images. Registration parameters are tuned for the cases listed registration case. The input images that are cropped to the area around the left atrium can be used as well, which would improve the final registration result.

Usage

Examples, Use Cases & Tutorials

  • This module is meant to be used for cardiac LGE-MRI, MRA and CT scans acquired at different time points or across different patients.

Quick Tour of Features and Use

The following are the inputs and outputs

  • Volume One (Fixed): Select the LGE-MRI, MRA or CT Image
  • Volume Two (Moving): Select the LGE-MRI or MRA image
  • Output Volume : The registration result
  • Imaging modality: The types of images that are being registered (e.g LGE-MRI, MRA, CT, Acute Scar)

More Information