Difference between revisions of "2014 Project Week:PercutaneousApproachAnalysis"
From NAMIC Wiki
(23 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
<gallery> | <gallery> | ||
Image:PW-SLC2014.png|[[2014_Winter_Project_Week#Projects|Projects List]] | Image:PW-SLC2014.png|[[2014_Winter_Project_Week#Projects|Projects List]] | ||
− | Image:PathViewAyamadaAHM2014.png|Path | + | Image:PathViewAyamadaAHM2014.png|Calculated Path Candidates |
− | Image:ModulePane.png|Module | + | Image:ApproachImageAyamada2014.png|Module Overview |
− | Image: | + | Image:ModulePane.png|Module Panel |
+ | Image:ExtendCandidatePath.png|YouTube: http://youtu.be/jI_4IZIT4iI | ||
</gallery> | </gallery> | ||
==Key Investigators== | ==Key Investigators== | ||
− | *Atsushi Yamada (Shiga University of Medical Science) | + | *Atsushi Yamada (Shiga University of Medical Science, Japan, ayamada@belle.shiga-med.ac.jp) |
*Junichi Tokuda (BWH) | *Junichi Tokuda (BWH) | ||
− | *Koichiro Murakami (Shiga University of Medical Science) | + | *Koichiro Murakami (BWH, Shiga University of Medical Science, Japan) |
− | |||
==Project Description== | ==Project Description== | ||
Line 24: | Line 24: | ||
<div style="width: 27%; float: left; padding-right: 3%;"> | <div style="width: 27%; float: left; padding-right: 3%;"> | ||
<h3>Approach, Plan</h3> | <h3>Approach, Plan</h3> | ||
− | * | + | * Implement function to display maximum and minimum length paths |
+ | * Implement function to display maximum and minimum oblique paths | ||
+ | * Fix bugs | ||
</div> | </div> | ||
<div style="width: 27%; float: left; padding-right: 3%;"> | <div style="width: 27%; float: left; padding-right: 3%;"> | ||
<h3>Progress</h3> | <h3>Progress</h3> | ||
− | * | + | * Created this page (1/6) |
+ | * Private GitHub repository: [https://github.com/ayamada0614/PercutaneousPathDesigner.git Percutaneous Path Designer module] | ||
+ | * Implemented planning part (1/6) | ||
+ | * Implemented needle path selection part (1/6) | ||
+ | * [Planning procedure] | ||
+ | ** Set a target point, obstacles, region of insertion candidate | ||
+ | ** Obtain the path candidates with visualization as sun ray | ||
+ | ** Select one path from the path candidates by using the slider interface | ||
+ | ** Find a needle insertion point obtained by extending the tip of the selected needle path candidate | ||
</div> | </div> | ||
</div> | </div> |
Latest revision as of 03:42, 25 July 2014
Home < 2014 Project Week:PercutaneousApproachAnalysisYouTube: http://youtu.be/jI_4IZIT4iI
Key Investigators
- Atsushi Yamada (Shiga University of Medical Science, Japan, ayamada@belle.shiga-med.ac.jp)
- Junichi Tokuda (BWH)
- Koichiro Murakami (BWH, Shiga University of Medical Science, Japan)
Project Description
Objective
- The goals of the entire project are to display pathways to a target tumor avoiding anatomical structures including arteries and other organs and to use these pathways for planning.
- The goal of this project is to implement the function to pick up geometrically specific pathways (short distance, small oblique and so on) from calculated pathway candidates.
Approach, Plan
- Implement function to display maximum and minimum length paths
- Implement function to display maximum and minimum oblique paths
- Fix bugs
Progress
- Created this page (1/6)
- Private GitHub repository: Percutaneous Path Designer module
- Implemented planning part (1/6)
- Implemented needle path selection part (1/6)
- [Planning procedure]
- Set a target point, obstacles, region of insertion candidate
- Obtain the path candidates with visualization as sun ray
- Select one path from the path candidates by using the slider interface
- Find a needle insertion point obtained by extending the tip of the selected needle path candidate