= Non-rigid Groupwise Registration =
  
= Optimal Mass Transport Registration =
+
We aim at providing efficient groupwise registration algorithms
 +
for population analysis of anatomical structures.
 +
Here we extend a previously demonstrated entropy based groupwise registration method
 +
to include a free-form deformation model based on B-splines.
 +
We provide
 +
an efficient implementation using stochastic gradient descents
 +
in a multi-resolution setting.
 +
We demonstrate the method in application to a set of 50 MRI brain scans
 +
and compare the results to a pairwise approach
 +
using segmentation labels to evaluate the quality of alignment.
 +
Our results indicate that increasing the complexity of the deformation model
 +
improves registration accuracy significantly, especially at cortical regions.
  
The aim of this project to provide a computationaly efficient non-rigid/elastic image registration algorithm based on the Optimal Mass Transport theory. We use the Monge-Kantorovich formulation of the Optimal Mass Transport problem and implement the solution proposed by Haker et al. using multi-resolution and multigrid techniques to speed up the convergence. We also leverage the computation power of general purpose graphics processing units available on standard desktop computing machines to exploit the inherent parallelism in our algorithm.
+
= Description =
 +
 
 +
We first describe
 +
the stack entropy cost function and the B-spline based deformation model.
 +
Then we discuss implementation details.
 +
Next, we compare groupwise registration to the pairwise method and
 +
evaluate both methods using label prediction values.
 +
 
 +
 
 +
''Objective Function''
 +
 
 +
[[Image:GroupwiseStackBiModal.PNG|thumb|350px|Figure 1: On the left is shown a stack of images
 +
and a sample pixel stack around a cortical region. On the left is shown the Gaussian(blue) fittet to
 +
a real sample from the dataset we used along with the non-parametric density estimate(red).
 +
Note that the distribution is bi-modal because of white matter-gray matter transaction.]]
 +
 
 +
In order to align all subjects in the population,
 +
we consider sum of pixelwise entropies as a joint alignment criterion.
 +
The justification for this approach is that if the images are aligned properly,
 +
intensity values at corresponding coordinate locations from all the images
 +
will form a low entropy distribution.
 +
This approach does not require the use of a reference subject; all
 +
subjects are simultenously driven to the common tendency of the population.
 +
 
 +
We employ a kernel based density estimation scheme to estimate univariate entropies.
 +
Using the entropy measure we obtain a better treatment of transitions between different
 +
tissue types, such as gray matter-white matter transitions in the cortical regions
 +
where intensity distributions can be bi-modal as shown in Figure 1.
 +
 
 +
 
 +
 
 +
''Deformation Model''
 +
 
 +
[[Image:GroupwiseBspline.png|thumb|350px|Figure 2: An example deformation field. The local neighborhood affecting the deformation is overlayed on the image.]]
 +
 
 +
For the nonrigid deformation model,
 +
we define a combined transformation consisting of
 +
a global and a local component
 +
 
 +
:<math>
 +
T(\mathbf{x}) = T_{local}({T_{global}(\mathbf{x})})
 +
</math>
 +
 
 +
where <math>T_{global}</math> is a twelve parameter affine transform and
 +
<math>T_{local}</math> is a deformation model based on B-splines.
 +
 
 +
The free form deformation can be written as the 3-D tensor product
 +
of 1-D cubic B-splines.
 +
 
 +
:<math>
 +
T_{local}(\mathbf{x}) = \mathbf{x} + \sum_{l=0}^3\sum_{m=0}^3\sum_{n=0}^3 B_l(u)B_m(v)B_n(w) \Phi_{i+l,j+m,k+n}
 +
</math>
 +
 
 +
 
 +
 +
where <math>B_l</math> is <math>l</math>'th cubic B-spline basis function. <math>(u,v,w)</math> is the distance
 +
to <math>(x,y,z)</math> from the control point <math>\Phi_{i,j,k}</math> as shown in Figure 2.
 +
 
 +
The deformation of a given point can be found using only the control points in the neighborhood of the given point. Therefore,
 +
optimization of the objective function can be implemented efficiently.
 +
 
 +
 
 +
''Implementation''
 +
 
 +
[[Image:GroupwiseIncreasingScale.PNG|thumb|350px|Figure 3: A registration schedule using gradually increasing deformation field complexity. From left to right deformation fields for increasing deformation field complexity. ]]
 +
 
 +
We provide an efficient optimization scheme by using line search with the gradient descent algorithm.
 +
For computational efficiency, we employ a stochastic subsampling procedure.
 +
In each iteration of the algorithm,
 +
a random subset is drawn from all samples and the objective function is evaluated
 +
only on this sample set.
 +
 
 +
To obtain a dense deformation field capturing anatomical variations at different scales,
 +
we gradually increase the complexity of the deformation field by refining the grid of B-spline control points.
  
= Description =
 
  
The Optimal Mass Transport problem was first formulated by a Frech engineer Gasper Monge in 1781, and was given a modern formulation in the work of Kantorovich and, therefore, is now known as the Monge-Kantorovich problem. We extend the work by Haker et al. who compute the optimal warp from a first order partial differential equation, an improvement over earlier proposed higher order methods and those based on linear programming. We implement the algorithm using a coarse-to-fine strategy resulting in phenomenol improvement in convergence. The algorithm also involves inverting the Laplacian in each iteration, which we perform using multigrid methods for even faster per iteration computation times. This method has a number of distinguishing characteristics:
+
[[Image:GroupwiseMultiResolution.PNG|thumb|350px|Figure 4: An example showing the multi-resolution scheme. The registration is first performed at a coarse scale by downsampling the input.
 +
Results from coarser scales are used to initialize
 +
optimization at finer scales. Also note that the objective function is only evaluated on a small subset of input points. ]]
  
# It is a parameter free method.
+
As in every iterative search algorithm, local minima pose a significant problem.  
# It utillizes all of the grayscale data in both images.
+
To avoid local minima we use a multi-resolution optimization scheme for each resolution level of the deformation field.
# It is symmetrical; the optimal mapping from image A to image B is the inverse of the optimal mapping from B to A.
 
# No landmarks need to be specified.
 
# The minimizer of the functional involved is unique; there are no local minimizers.
 
# The algorithm is designed to take into account changes in densities that result from changes in area or volume.
 
  
''Algorithm''
+
We implemented our groupwise registration method in a multi-threaded fashion using Insight Toolkit(ITK)
 +
and made the implementation publicly available [http://www.na-mic.org/svn/NAMICSandBox/trunk/MultiImageRegistration/ (code)].
  
The flowchart of the algorithm is shown in the following figure.
+
''Results''
  
[[Image:OMT_Algorithm.jpg| Optimal Mass Transport Algorithm | center]]
+
[[Image:GroupwiseMeanImages.png|thumb|350px|Figure 5:  Central slices of 3D volumes for groupwise registration. Rows show mean and standard deviation images followed by label overlap images for GM, WM and CSF labels. Columns display the results for affine and B-splines with grid spacing 32, 16 and 8 voxels, respectively. ]]
 +
[[Image:GroupwiseBarsWMGM.png|thumb|350px|Figure 6: GM, WM DICE measures computed for different deformation field resolution levels. Blue bars show the results for groupwise registration and the red bars show the results for registration to the mean setting.]]
 +
[[Image:GroupwiseBarsManual.png|thumb|350px|Figure 7: DICE measures for manually segmented labels. Bars correspond to the same setting as in figure 6. ]]
  
<br/>
 
  
''Multi-resolution Approach''
+
We tested the groupwise registration algorithm on a MR brain dataset.
 +
The dataset consists of 50 MR brain images of three subgroups:
 +
schizophrenics, affected disorder and normal control patients.
 +
MR images are T1 scans with 256x256x128 voxels
 +
and 0.9375x0.9375x1.5 mm<sup>3</sup> spacing.
 +
For each image in the dataset, an automatic tissue classification
 +
was performed, yielding gray matter (GM), white matter (WM) and cerebro-spinal
 +
fluid (CSF) labels. In addition, manual segmentations of four subcortical regions
 +
(left and right hippocampus and amygdala) and four cortical regions (left and right superior temporal
 +
gyrus and para-hippocampus) were available for each MR image.
  
Performing image registration using a multi-resolution approach is widely used to improve speed, accuracy and robustness. Registration is first performed at a coarse scale. The spatial mapping determined at coarse scale is then used to initialize registration at the next finer scale. This process is repeated until it reaches the finest scale. Our coarse-to-fine hierarchy comprises of three levels and we use bi-cubic interpolation to interpolate results from coarse to fine grid. This process is depicted in the following figure.
+
Increasing the complexity of the deformation model improves the
<br/>
+
accuracy of prediction. An interesting open problem is automatically
 +
identifying the appropriate deformation complexity before the
 +
registration overfits and the accuracy of prediction goes down. We
 +
also note that the alignment of the subcortical structures is much
 +
better than that of the cortical regions. It is not surprising as the
 +
registration algorithm does not use the information about geometry of the cortex
 +
to optimize the alignment of the cortex. In addition, it has
 +
been often observed that the cortical structures exhibit higher
 +
variability across subjects when considered in the 3D volume rather
 +
than modelled on the surface.
  
[[Image:Multilevel_diagram.jpg| Multi-resolution Implementation | 800px | center]]
+
Our experiments highlight the need for further research in developing
 +
evaluation criteria for image alignment. We used the standard Dice
 +
measure, but it is not clear that this measurement captures all the
 +
nuances of the resulting alignment.
  
''Progress''
+
Comparing the groupwise registration to the pairwise approach, we
 +
observe that the sharpness of the mean images and the tissue overlaps
 +
in Figure 5 look visually similar. From Figures 6 and 7, we note that
 +
groupwise registration performs slightly better than the pairwise
 +
setting in most of the cases, especially as we increase the complexity
 +
of the warp. This suggests that considering the population as a whole
 +
and registering subjects jointly brings the population into better
 +
alignment than matching each subject to a mean template
 +
image. However, the advantage shown here is only slight; more
 +
comparative studies are needed of the two approaches.
  
Below we show the results from registration of two 3D brain MRI datasets. The first data set was pre-operative while the second data set was acquired during surgery (craniotomy). Both were resampled to 256*256*256 for uniform voxel size and the skull was removed. We show the results from two axial slices of the 3D brain volumes. The sag and compression areas can easily be seen in the deformed grid shown below. The reults shown are after 3600 iterations, requiring less than 15 minutes of computation time (Dual Xeon 1.6GHz + nVidia GeForce 8800 GX GPU. The optimal computation time was found to occur for a grid size of 128*128*128 where about 1000 iterations execute in less than 15 seconds. This is due to the memory limitations on the graphics card used.
+
We compare our groupwise algorithm to a pairwise method where we register
 +
each subject to the mean intensity using sum of square differences.
 +
During each iteration we consider the mean image as a reference image
 +
and register
 +
every subject to the mean image using sum of squared differences.  
 +
After each iteration the mean image is updated and pairwise registrations are performed until convergence.
  
* [[Image:Results_brain_sag.JPG | Visual Results | 1000px]]
+
The images in Figure 5 show central slices of 3D images after registration.
 +
Visually, mean images get sharper and variance images becomes darker, especially around central ventricles and cortical regions.
 +
We can observe that anatomical variability at cortical regions causes significant blur for
 +
GM, WM and CSF structures using affine registration.
 +
Finer scales of B-spline deformation fields capture a significant part of this anatomical variability and
 +
the tissue label overlap images get sharper.
  
3D Registration Results on axial slices. We visualize the optimal transport map (right) in the form of a vector field corresponding to the directions of deformation between pre-op (left)
+
=Asymmetric Image-Template Registration=
and post-op (center) brains. Data size 256*256*256.
 
  
''Project Status''
+
A natural requirement in pairwise image registration is that the resulting deformation is independent of the order of the images. This constraint is typically achieved via a symmetric cost function and has been shown to reduce the effects of local optima. Consequently, symmetric registration has been successfully applied to pairwise image registration as well as the spatial alignment of individual images with a template. However, recent work has shown that the relationship between
* 2D Multi-resolution Registration using Optimal Mass Transport implemented.
+
an image and a template is fundamentally asymmetric. In this work, we develop a method that reconciles the practical advantages of symmetric registration with the asymmetric nature of image-template registration by adding a simple correction factor to the symmetric cost function. We instantiate our model within a log-domain diffeomorphic registration
* 3D Multi-resolution Registration using Optimal Mass Transport of Brain sag datasets implemented.
+
framework. Our experiments show exploiting the asymmetry in image-template registration improves alignment in the image coordinates.
* Currently working on validating 3D registration results.
 
  
 
= Key Investigators =
 
= Key Investigators =
  
* Georgia Tech: Tauseef ur Rehman, Gallagher Pryor, John Melonakos, Allen Tannenbaum
+
* MIT: Mert R. Sabuncu, B.T. Thomas Yeo, Koen Van Leemput, Serdar K. Balci, Polina Golland.
 +
* Harvard: Sylvain Bouix, Martha E. Shenton, Bruce Fischl, W.M. (Sandy) Wells.
 +
* Kitware: Brad Davis, Louis Ibanez.
  
 
= Publications =
 
= Publications =
  
''In press''
 
  
* T. Rehman and A. Tannenbaum. Multigrid Optimal Mass Transport for Image Registration and Morphing. SPIE Computation Imaging V, 2007
+
[http://www.na-mic.org/publications/pages/display?search=Projects%3AGroupwiseRegistration&submit=Search&words=all&title=checked&keywords=checked&authors=checked&abstract=checked&sponsors=checked&searchbytag=checked| NA-MIC Publications Database on Groupwise Registration]
* T. Rehman, G. Pryor and A. Tannenbaum. GPU Enhanced Multigrid Optimal Mass Transport for Image Registration and Morphing. Publication in submission.
+
 
* T. Rehman, G. Pryor, J. Melonakos and A. Tannenbaum. Multiresolution 3D Nonrigid Registration via Optimal Mass Transport. Publication in submission.
+
[[Category: Registration]] [[Category:Segmentation]] [[Category:MRI]] [[Category:Schizophrenia]]

Latest revision as of 20:07, 11 May 2010

Home < Projects:GroupwiseRegistration
Back to NA-MIC Collaborations, MIT Algorithms

Non-rigid Groupwise Registration

We aim at providing efficient groupwise registration algorithms for population analysis of anatomical structures. Here we extend a previously demonstrated entropy based groupwise registration method to include a free-form deformation model based on B-splines. We provide an efficient implementation using stochastic gradient descents in a multi-resolution setting. We demonstrate the method in application to a set of 50 MRI brain scans and compare the results to a pairwise approach using segmentation labels to evaluate the quality of alignment. Our results indicate that increasing the complexity of the deformation model improves registration accuracy significantly, especially at cortical regions.

Description

We first describe the stack entropy cost function and the B-spline based deformation model. Then we discuss implementation details. Next, we compare groupwise registration to the pairwise method and evaluate both methods using label prediction values.


Objective Function

Figure 1: On the left is shown a stack of images and a sample pixel stack around a cortical region. On the left is shown the Gaussian(blue) fittet to a real sample from the dataset we used along with the non-parametric density estimate(red). Note that the distribution is bi-modal because of white matter-gray matter transaction.

In order to align all subjects in the population, we consider sum of pixelwise entropies as a joint alignment criterion. The justification for this approach is that if the images are aligned properly, intensity values at corresponding coordinate locations from all the images will form a low entropy distribution. This approach does not require the use of a reference subject; all subjects are simultenously driven to the common tendency of the population.

We employ a kernel based density estimation scheme to estimate univariate entropies. Using the entropy measure we obtain a better treatment of transitions between different tissue types, such as gray matter-white matter transitions in the cortical regions where intensity distributions can be bi-modal as shown in Figure 1.


Deformation Model

Figure 2: An example deformation field. The local neighborhood affecting the deformation is overlayed on the image.

For the nonrigid deformation model, we define a combined transformation consisting of a global and a local component

[math] T(\mathbf{x}) = T_{local}({T_{global}(\mathbf{x})}) [/math]

where [math]T_{global}[/math] is a twelve parameter affine transform and [math]T_{local}[/math] is a deformation model based on B-splines.

The free form deformation can be written as the 3-D tensor product of 1-D cubic B-splines.

[math] T_{local}(\mathbf{x}) = \mathbf{x} + \sum_{l=0}^3\sum_{m=0}^3\sum_{n=0}^3 B_l(u)B_m(v)B_n(w) \Phi_{i+l,j+m,k+n} [/math]


where [math]B_l[/math] is [math]l[/math]'th cubic B-spline basis function. [math](u,v,w)[/math] is the distance to [math](x,y,z)[/math] from the control point [math]\Phi_{i,j,k}[/math] as shown in Figure 2.

The deformation of a given point can be found using only the control points in the neighborhood of the given point. Therefore, optimization of the objective function can be implemented efficiently.


Implementation

Figure 3: A registration schedule using gradually increasing deformation field complexity. From left to right deformation fields for increasing deformation field complexity.

We provide an efficient optimization scheme by using line search with the gradient descent algorithm. For computational efficiency, we employ a stochastic subsampling procedure. In each iteration of the algorithm, a random subset is drawn from all samples and the objective function is evaluated only on this sample set.

To obtain a dense deformation field capturing anatomical variations at different scales, we gradually increase the complexity of the deformation field by refining the grid of B-spline control points.


Figure 4: An example showing the multi-resolution scheme. The registration is first performed at a coarse scale by downsampling the input. Results from coarser scales are used to initialize optimization at finer scales. Also note that the objective function is only evaluated on a small subset of input points.

As in every iterative search algorithm, local minima pose a significant problem. To avoid local minima we use a multi-resolution optimization scheme for each resolution level of the deformation field.

We implemented our groupwise registration method in a multi-threaded fashion using Insight Toolkit(ITK) and made the implementation publicly available (code).

Results

Figure 5: Central slices of 3D volumes for groupwise registration. Rows show mean and standard deviation images followed by label overlap images for GM, WM and CSF labels. Columns display the results for affine and B-splines with grid spacing 32, 16 and 8 voxels, respectively.
Figure 6: GM, WM DICE measures computed for different deformation field resolution levels. Blue bars show the results for groupwise registration and the red bars show the results for registration to the mean setting.
Figure 7: DICE measures for manually segmented labels. Bars correspond to the same setting as in figure 6.


We tested the groupwise registration algorithm on a MR brain dataset. The dataset consists of 50 MR brain images of three subgroups: schizophrenics, affected disorder and normal control patients. MR images are T1 scans with 256x256x128 voxels and 0.9375x0.9375x1.5 mm3 spacing. For each image in the dataset, an automatic tissue classification was performed, yielding gray matter (GM), white matter (WM) and cerebro-spinal fluid (CSF) labels. In addition, manual segmentations of four subcortical regions (left and right hippocampus and amygdala) and four cortical regions (left and right superior temporal gyrus and para-hippocampus) were available for each MR image.

Increasing the complexity of the deformation model improves the accuracy of prediction. An interesting open problem is automatically identifying the appropriate deformation complexity before the registration overfits and the accuracy of prediction goes down. We also note that the alignment of the subcortical structures is much better than that of the cortical regions. It is not surprising as the registration algorithm does not use the information about geometry of the cortex to optimize the alignment of the cortex. In addition, it has been often observed that the cortical structures exhibit higher variability across subjects when considered in the 3D volume rather than modelled on the surface.

Our experiments highlight the need for further research in developing evaluation criteria for image alignment. We used the standard Dice measure, but it is not clear that this measurement captures all the nuances of the resulting alignment.

Comparing the groupwise registration to the pairwise approach, we observe that the sharpness of the mean images and the tissue overlaps in Figure 5 look visually similar. From Figures 6 and 7, we note that groupwise registration performs slightly better than the pairwise setting in most of the cases, especially as we increase the complexity of the warp. This suggests that considering the population as a whole and registering subjects jointly brings the population into better alignment than matching each subject to a mean template image. However, the advantage shown here is only slight; more comparative studies are needed of the two approaches.

We compare our groupwise algorithm to a pairwise method where we register each subject to the mean intensity using sum of square differences. During each iteration we consider the mean image as a reference image and register every subject to the mean image using sum of squared differences. After each iteration the mean image is updated and pairwise registrations are performed until convergence.

The images in Figure 5 show central slices of 3D images after registration. Visually, mean images get sharper and variance images becomes darker, especially around central ventricles and cortical regions. We can observe that anatomical variability at cortical regions causes significant blur for GM, WM and CSF structures using affine registration. Finer scales of B-spline deformation fields capture a significant part of this anatomical variability and the tissue label overlap images get sharper.

Asymmetric Image-Template Registration

A natural requirement in pairwise image registration is that the resulting deformation is independent of the order of the images. This constraint is typically achieved via a symmetric cost function and has been shown to reduce the effects of local optima. Consequently, symmetric registration has been successfully applied to pairwise image registration as well as the spatial alignment of individual images with a template. However, recent work has shown that the relationship between an image and a template is fundamentally asymmetric. In this work, we develop a method that reconciles the practical advantages of symmetric registration with the asymmetric nature of image-template registration by adding a simple correction factor to the symmetric cost function. We instantiate our model within a log-domain diffeomorphic registration framework. Our experiments show exploiting the asymmetry in image-template registration improves alignment in the image coordinates.

Key Investigators

  • MIT: Mert R. Sabuncu, B.T. Thomas Yeo, Koen Van Leemput, Serdar K. Balci, Polina Golland.
  • Harvard: Sylvain Bouix, Martha E. Shenton, Bruce Fischl, W.M. (Sandy) Wells.
  • Kitware: Brad Davis, Louis Ibanez.

Publications

NA-MIC Publications Database on Groupwise Registration