Present: Doug, Marc, Marek, Gordon, Sylvain, Katharina, Toshiro
Scanning Update:
- 7 subjects were scanned yesterday. Biggest logistical hurdle is reconstruction time--holds up scanning for 25 minutes
- Data is on the network, but needs to be assigned case numbers
- Sylvain made tensors for the new cases
- One case had FAT artifact, may be bad enough that we will have to bring the subject back
- There is a bug in Slicer where the 3D view and the slice view are decoupled
- 2 cases are sheared strangely--the oblique acquisition may be causing this, may be measurement frame.
- Gordon suggested that we experiment with scanning a subject with head rotated at 45deg.
- Also, if possible the scheme of gradient directions should be changed (need to talk to NanQuei)
DWI inspection for new data:
- Gordon presented a method for inspecting sequences of DWIs to look for drops in signal or other artifacts. Baseline images and gradient images in a composite, cycling through slices to see abrupt changes in intensity.
- With the new data, a lot of problems are obvious: zipper lines, dropped DWIs, uneven drops in intensity within a single DWI, motion artifacts, FAT artifact (shows up well in AvGradient image)
- PNL can use this method to inspect every new DTI case that comes in