Difference between revisions of "2012 Winter Project Week:SlidingOrgans"

From NAMIC Wiki
Jump to: navigation, search
(Created page with '__NOTOC__ <gallery> Image:PW-SLC2012.png|Projects List Image:MP_RAGE_PRECONTRAST.png‎|An example T1 weighted image from a patient with TBI…')
 
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
<gallery>
 
<gallery>
 
Image:PW-SLC2012.png|[[2012_Winter_Project_Week#Projects|Projects List]]
 
Image:PW-SLC2012.png|[[2012_Winter_Project_Week#Projects|Projects List]]
Image:MP_RAGE_PRECONTRAST.png‎|An example T1 weighted image from a patient with TBI
 
 
</gallery>
 
</gallery>
  
Line 16: Line 15:
  
 
<h3>Objective</h3>
 
<h3>Objective</h3>
TODO
+
* Conventional deformable image registration enforces smooth motion, causing inaccurate displacement measurements near sliding motion.
 +
* Sliding motion is common in intra-subject 4D image registration problems, for example respiration-induced sliding of the lungs and abdominal organs against the chest wall.
 +
* We have developed an image registration algorithm based on anisotropic diffusion that handles sliding motion.
 
</div>
 
</div>
  
Line 22: Line 23:
  
 
<h3>Approach, Plan</h3>
 
<h3>Approach, Plan</h3>
*TODO
+
* Continue algorithm validation experiments in 4D chest CT.
 
+
* Improve CLI documentation and user interface.
 +
* Fix user experience issues of integration of TubeTK CLIs into Slicer 4.
  
 
</div>
 
</div>
Line 30: Line 32:
  
 
<h3>Progress</h3>
 
<h3>Progress</h3>
 +
* Improved Slicer's handling of external module paths that contain non-parseable executables
 +
* Cleaned up TubeTK build output destinations
 +
* Cleaned up CLI documentation and command-line options - rename parameters, improve descriptions, remove confusing options (inspired by BRAINSFit registration documentation)
  
  

Latest revision as of 15:10, 13 January 2012

Home < 2012 Winter Project Week:SlidingOrgans

Registration in the presence of sliding between organs

Key Investigators

  • Kitware: Danielle Pace, Stephen Aylward
  • UNC: Marc Niethammer

Objective

  • Conventional deformable image registration enforces smooth motion, causing inaccurate displacement measurements near sliding motion.
  • Sliding motion is common in intra-subject 4D image registration problems, for example respiration-induced sliding of the lungs and abdominal organs against the chest wall.
  • We have developed an image registration algorithm based on anisotropic diffusion that handles sliding motion.

Approach, Plan

  • Continue algorithm validation experiments in 4D chest CT.
  • Improve CLI documentation and user interface.
  • Fix user experience issues of integration of TubeTK CLIs into Slicer 4.

Progress

  • Improved Slicer's handling of external module paths that contain non-parseable executables
  • Cleaned up TubeTK build output destinations
  • Cleaned up CLI documentation and command-line options - rename parameters, improve descriptions, remove confusing options (inspired by BRAINSFit registration documentation)


Delivery Mechanism

This work will be delivered to the NA-MIC Kit as a Slicer extension as a CLI distributed in TubeTK (http://public.kitware.com/Wiki/TubeTK)