The case study is liver tumor cryoablation. | The case study is liver tumor cryoablation. | ||
In this tutorial, the three steps are performed as shown the figure on right side. | In this tutorial, the three steps are performed as shown the figure on right side. | ||
− | (1) In MR-planning CT image registration, we can obtain the deformed MR image and the Bspline transformation matrix T1 by using pre-procedure contrast enhanced MRI and mask image. | + | *(1) In MR-planning CT image registration, we can obtain the deformed MR image and the Bspline transformation matrix T1 by using pre-procedure contrast enhanced MRI and mask image. |
− | (2) In plannning CT-intraprocedure CT image registration, we can obtain the deformed planning CT image and the Bspline transformation matrix T2. | + | *(2) In plannning CT-intraprocedure CT image registration, we can obtain the deformed planning CT image and the Bspline transformation matrix T2. |
− | (3) In MR-intraprocedure CT image registration, we can obtain the deformed MR image by using T1 and T2 BSpline transformation matrices. | + | *(3) In MR-intraprocedure CT image registration, we can obtain the deformed MR image by using T1 and T2 BSpline transformation matrices. |
For non-rigid registration, BRAINSFitIGT and BRAINSResamle modules are used. | For non-rigid registration, BRAINSFitIGT and BRAINSResamle modules are used. | ||
In this tutorial, we will show that 3D Slicer with BRAINSFitIGT module allows performing non-rigid image registration and BRAINSResample module allows performing non-rigid image deformation using Bspline transform matrix. | In this tutorial, we will show that 3D Slicer with BRAINSFitIGT module allows performing non-rigid image registration and BRAINSResample module allows performing non-rigid image deformation using Bspline transform matrix. |
Revision as of 22:44, 3 June 2011
Home < Non-rigid MR-CT Image RegistrationContents
Non-rigid MR-CT Image Registration Tutorial
Overview
This tutorial demonstrates how to perform MR-CT and Ct-CT non-rigid image registrations. The case study is liver tumor cryoablation. In this tutorial, the three steps are performed as shown the figure on right side.
- (1) In MR-planning CT image registration, we can obtain the deformed MR image and the Bspline transformation matrix T1 by using pre-procedure contrast enhanced MRI and mask image.
- (2) In plannning CT-intraprocedure CT image registration, we can obtain the deformed planning CT image and the Bspline transformation matrix T2.
- (3) In MR-intraprocedure CT image registration, we can obtain the deformed MR image by using T1 and T2 BSpline transformation matrices.
For non-rigid registration, BRAINSFitIGT and BRAINSResamle modules are used. In this tutorial, we will show that 3D Slicer with BRAINSFitIGT module allows performing non-rigid image registration and BRAINSResample module allows performing non-rigid image deformation using Bspline transform matrix.
Tutorials
Non-rigid MR-CT Image Registration Module tutorial : to perform MR-CT and CT-CT image registration [ppt] [pdf]
Tutorial materials
ShapeAnalysisModule data :
- Link to NITRC
- or directly here : ShapeAnalysisModuleTutorialData_TutorialContestSummer2011.zip