Difference between revisions of "Projects:DTI DWI QualityControl"
Line 23: | Line 23: | ||
This approach can also be employed to correct data: Using a leave-one-out scheme, we iteratively determine the best candidate DWI image for exclusion as the one with optimal improvement in the corresponding DTI's entropy measure. This removal of DWI's continues until either DTI image is not longer classified in the rejection class. | This approach can also be employed to correct data: Using a leave-one-out scheme, we iteratively determine the best candidate DWI image for exclusion as the one with optimal improvement in the corresponding DTI's entropy measure. This removal of DWI's continues until either DTI image is not longer classified in the rejection class. | ||
− | [[Image:Correction_Figure_copy.png|400px|thumb|right| The correction | + | [[Image:Correction_Figure_copy.png|400px|thumb|right| The correction result (top right image) shows visible improvement in contrast within the cingulum and fornix tracts. The FA profiles of the genu and splenium tracts (bottom, red: uncorrected, blue: corrected image) show higher FA profiles for the corrected image.]] |
= Publications = | = Publications = |
Revision as of 20:49, 7 December 2011
Home < Projects:DTI DWI QualityControlBack to UNC Algorithms
Diffusion Tensor and Diffusion Weighted Imaging Quality Control
DWIs data suffer from inherent low SNR, overall long scanning time of multiple directional encoding with correspondingly large risk to encounter several kinds of artifacts. These artifacts can be too severe for a correct and stable estimation of the diffusion tensor. Thus, a quality control (QC) procedure is absolutely necessary for DTI studies. We are developing a framework, called DTIPrep, for assessing and correcting DWIs and DTI.
Description
Current framework for DWI QC
DTIPrep is the first comprehensive and fully automatic pre-processing tool for DWI and DTI quality control can provide a crucial piece for robust DTI analysis studies. The protocoling, reporting, visual controlling and data correction capabilities are used to produce high consistence and inter-rater reliable QC results. This framework is organized by pipeline steps include: 1) image info checking, 2) diffusion info checking, 3) Slice-wise intensity checking, 4) Interlace-wise intensity checking, 5) Averaging baseline images, 6) Eddy current and motion correction, 7) gradient-wise checking of residual motion/deformations, 8) Computing DTI measurements and saving and 9) Optional visual QC.
Ongoing extension using DTI QC
In our ongoing research, we are extending our QC procedures to include a QC step based on the derived DTI data. This step detects and potentially removes residual artifacts that are not commonly detected in the individual DWIs. In our large scale population studies, we observed several such artifacts, most specifically an artifact of "dominating direction" (see figure to the right). In order to detect such artifacts, we propose a new approach via the entropy of the Principal Direction (PD) histogram computed over the major region of the image (e.g. the full brain). Given a prior knowledge of expected entropy values for acceptable scans, the quality of the DTI image is categorized into acceptable, suspicious and highly suspicious/rejection categories using calculated the standard scores.
This approach can also be employed to correct data: Using a leave-one-out scheme, we iteratively determine the best candidate DWI image for exclusion as the one with optimal improvement in the corresponding DTI's entropy measure. This removal of DWI's continues until either DTI image is not longer classified in the rejection class.
Publications
Key Investigators
- UNC Algorithms: Mahshid Farzinfar, Zhexing Liu, Martin Styner, Clement Vachet
- Utah Algorithms: Tom Fletcher, Ross Whitaker, Guido Gerig, Sylvain Gouttard
Links
- DTIPrep on NITRC