''Project Status''
 
''Project Status''
 
* 2D Multi-resolution Registration using Optimal Mass Transport implemented.
 
* 2D Multi-resolution Registration using Optimal Mass Transport implemented.
 +
 
* 3D Multi-resolution Registration using Optimal Mass Transport of Brain sag datasets implemented.
 
* 3D Multi-resolution Registration using Optimal Mass Transport of Brain sag datasets implemented.
* 3D Registration of White Matter MRI data and white matter atlas implemented.
+
 
 +
* 3D Registration of White Matter MRI data and white matter atlas implemented. The proposed new algorithm and the preliminary results are shown below:
 +
 
 +
* [[Image:Wm_2_atlas_omt.jpg | Proposed Algorithm | 800px | center]]
 +
 
 +
* [[Image:Whitematter_tessalation.jpg | white matter to Atlas Registration Results | 800px | center]]
 +
 
 
* An Efficient Numerical Implementation of the OMT algorithm with explicit projections to the mass preserving constraint completed. The projection step is done using a Modified Sequential Quadratic Programming (SQP) approach.
 
* An Efficient Numerical Implementation of the OMT algorithm with explicit projections to the mass preserving constraint completed. The projection step is done using a Modified Sequential Quadratic Programming (SQP) approach.
 
* Working on development of computing the mass transport using OcTrees for reduced computational cost.
 
* Working on development of computing the mass transport using OcTrees for reduced computational cost.

Revision as of 03:38, 13 April 2009

Home < Projects:OptimalMassTransportRegistration

Back to NA-MIC Collaborations, Georgia Tech Algorithms

Optimal Mass Transport

The aim of this project to provide a computationaly efficient non-rigid/elastic image registration algorithm based on the Optimal Mass Transport theory. We use the Monge-Kantorovich formulation of the Optimal Mass Transport problem and implement the solution proposed by Haker et al. using multi-resolution and multigrid techniques to speed up the convergence. We also leverage the computation power of general purpose graphics processing units available on standard desktop computing machines to exploit the inherent parallelism in our algorithm.

Description

The Optimal Mass Transport problem was first formulated by a Frech engineer Gasper Monge in 1781, and was given a modern formulation in the work of Kantorovich and, therefore, is now known as the Monge-Kantorovich problem. We extend the work by Haker et al. who compute the optimal warp from a first order partial differential equation, an improvement over earlier proposed higher order methods and those based on linear programming. We implement the algorithm using a coarse-to-fine strategy resulting in phenomenol improvement in convergence. The algorithm also involves inverting the Laplacian in each iteration, which we perform using multigrid methods for even faster per iteration computation times. This method has a number of distinguishing characteristics:

  1. It is a parameter free method.
  2. It utillizes all of the grayscale data in both images.
  3. It is symmetrical; the optimal mapping from image A to image B is the inverse of the optimal mapping from B to A.
  4. No landmarks need to be specified.
  5. The minimizer of the functional involved is unique; there are no local minimizers.
  6. The algorithm is designed to take into account changes in densities that result from changes in area or volume.

Algorithm

The flowchart of the algorithm is shown in the following figure.

Optimal Mass Transport Algorithm


Multi-resolution Approach

Performing image registration using a multi-resolution approach is widely used to improve speed, accuracy and robustness. Registration is first performed at a coarse scale. The spatial mapping determined at coarse scale is then used to initialize registration at the next finer scale. This process is repeated until it reaches the finest scale. Our coarse-to-fine hierarchy comprises of three levels and we use bi-cubic interpolation to interpolate results from coarse to fine grid. This process is depicted in the following figure.

Multi-resolution Implementation


The following figure shows the outline of processing for the OMT solver conducted on the GPU. Processing occurs in two major phases: evolution of the map from source to target volumes and time step adjustment. Each gray rectangle represents one Cg kernel executed on the GPU. Arrows indicate the flow of data volumes through the Cg kernels. The entire process in the figure, above is repeated left to right until convergence.

  • Brain Sag 3D Results


Progress

The algorithm was tested on a synthetic 3D dataset comprising of a sphere and deformed version of it. The deformation vector field for this experiment are shown below:

  • Synthetic Results

Below we show the results from registration of two 3D brain MRI datasets. The first data set was pre-operative while the second data set was acquired during surgery (craniotomy). Both were resampled to 256*256*256 for uniform voxel size and the skull was removed. We show the results on an axial and a coronal slice of the 3D brain volumes. The sag and compression areas can easily be seen in the deformed grid shown below. The reults shown are after 3600 iterations, requiring less than 15 minutes of computation time (Dual Xeon 1.6GHz + nVidia GeForce 8800 GX GPU. The optimal computation time was found to occur for a grid size of 128*128*128 where about 1000 iterations execute in less than 15 seconds. This is due to the memory limitations on the graphics card used. The results on an axial and coronal slice are shown below:


  • Brain Sag Results
  • Brain Sag 3D Results


Project Status

  • 2D Multi-resolution Registration using Optimal Mass Transport implemented.
  • 3D Multi-resolution Registration using Optimal Mass Transport of Brain sag datasets implemented.
  • 3D Registration of White Matter MRI data and white matter atlas implemented. The proposed new algorithm and the preliminary results are shown below:
  • Proposed Algorithm
  • white matter to Atlas Registration Results
  • An Efficient Numerical Implementation of the OMT algorithm with explicit projections to the mass preserving constraint completed. The projection step is done using a Modified Sequential Quadratic Programming (SQP) approach.
  • Working on development of computing the mass transport using OcTrees for reduced computational cost.

Key Investigators

  • Georgia Tech: Tauseef ur Rehman, Ivan Kolesov, Gallagher Pryor, Eldad Haber, Allen Tannenbaum
  • BWH: Sylvain Bouix, Yogesh Rathi, Ron Kikinis

Publications

Journals

  1. Eldad Haber, Tauseef Rehman, and Allen Tannenbaum. An Efficient Numerical Method for the Solution of the L2 Optimal Mass Transfer Problem. In submission - SIAM Journal of Scientific Computing, 2008.
  2. Tauseef Rehman, Eldad Haber, Gallagher Pryor, John Melonakos, and Allen Tannenbaum. 3D Nonrigid Registration via Optimal Mass Transport on the GPU. To appear in - Elsevier Journal of Medical Image Analysis, 2008.
  3. Tauseef Rehman, Eldad Haber, Gallagher Pryor, and Allen Tannenbaum. Fast Optimal Mass Transport for 2D Image Registration and Morphing. Accepted for - Elsevier Journal of Image and Vision Computing, 2008.

Conference articles

  1. Tauseef Rehman and Allen Tannenbaum. Multimodal Registration of White Matter Brain Data via Optimal Mass Transport. In Proceedings of Computational Biomechanics for Medicine-III, MICCAI, pages 27-35, 2008.
  2. G. Pryor, T. Rehman, S. Lankton, P. Vela, and A. Tannenbaum. Fast Optimal Mass Transport for Dynamic Active Contour Tracking on the GPU. In CDC, 2007.
  3. Tauseef Rehman, Gallagher Pryor, John Melonakos, and Allen Tannenbaum. Multi-resolution 3D Nonrigid Registration via Optimal Mass Transport on the GPU. In Proceedings of Computational Biomechanics for Medicine-II, MICCAI, pages 122-132, 2007.
  4. Tauseef Rehman, Gallagher Pryor, and Allen Tannenbaum. Fast Multigrid Optimal Mass Transport for Image Registration and Morphing. In Proceedings of British Machine Vision Conference, pages 102-111, 2007.
  5. Tauseef Rehman and Allen Tannenbaum. Multigrid Optimal Mass Transport for Image Registration and Morphing. In Proceedings of SPIE Conference on Computational Imaging V, pages 649810, 2007.