Difference between revisions of "2009 Summer Project Week TrigeminalNerve"
From NAMIC Wiki
MartaPeroni (talk | contribs) |
MartaPeroni (talk | contribs) |
||
Line 3: | Line 3: | ||
Image:PW2009-v3.png|[[2009_Summer_Project_Week|Project Week Main Page]] | Image:PW2009-v3.png|[[2009_Summer_Project_Week|Project Week Main Page]] | ||
Image:genuFAp.jpg|Scatter plot of the original FA data through the genu of the corpus callosum of a normal brain. | Image:genuFAp.jpg|Scatter plot of the original FA data through the genu of the corpus callosum of a normal brain. | ||
− | + | ||
</gallery> | </gallery> | ||
Line 16: | Line 16: | ||
<h3>Objective</h3> | <h3>Objective</h3> | ||
− | We are tuning and testing multimodal image registration in <a href="www.plastimatch.org">plastimatch </a> to allow accurate localization of the trigeminal nerve. The final objective is to register an atlas to patient CT, in order to avoid 3T MRI. The registration would allow the physician to identify the trigeminal nerve on the atlas and plan the Cyberknife treatment accordingly. | + | We are tuning and testing multimodal image registration in <a href="http://www.plastimatch.org">plastimatch </a> to allow accurate localization of the trigeminal nerve. The final objective is to register an atlas to patient CT, in order to avoid 3T MRI. The registration would allow the physician to identify the trigeminal nerve on the atlas and plan the Cyberknife treatment accordingly. |
Revision as of 16:39, 16 June 2009
Home < 2009 Summer Project Week TrigeminalNerve
Key Investigators
- PoliMI: Marta Peroni
- UMG: Maria Francesca Spadea
- MGH: Greg Sharp
Objective
We are tuning and testing multimodal image registration in <a href="http://www.plastimatch.org">plastimatch </a> to allow accurate localization of the trigeminal nerve. The final objective is to register an atlas to patient CT, in order to avoid 3T MRI. The registration would allow the physician to identify the trigeminal nerve on the atlas and plan the Cyberknife treatment accordingly.
Approach, Plan
Our approach is to crop and "threshold" the CT and to crop the atlas to obtain a more robust result. The output of Bspline deformable registration is than compared to the patient 3T MRI (whenever possible in the same modality - T1). The MRIs are acquired generally with CISS sequence.
Our plan for the project week is:
- solve issues with parameter handling between rigid and non-rigid stage
- investigate why the cropping is necessary for the registration to produce an output "acceptable" (TO BE DEFINED)
- investigate the thresholding
Progress
COME BACK SOON FOR MORE DETAILS...
References
- WILL BE ADDED SOON