Difference between revisions of "2011 Summer Project Week Breakout Session EMRegistration"
From NAMIC Wiki
Line 33: | Line 33: | ||
*CMTK takes ~1hr and is not a BSD license | *CMTK takes ~1hr and is not a BSD license | ||
*skull stripped input is not necessarily avail. for all input | *skull stripped input is not necessarily avail. for all input | ||
+ | *concatenation of multiple nonrigid transforms is also forthcoming in ITK4 | ||
+ | *Plastimatch was not designed for brain MRI, but it does have multiresolution | ||
+ | *2 track approach, using multiple versions that use different registration methods | ||
+ | *NA-MIC sandbox options: Andryi | ||
+ | *bootstrapping of transforms for saving time |
Revision as of 20:05, 22 June 2011
Home < 2011 Summer Project Week Breakout Session EMRegistrationContents
Summer Project Week Breakout Session: Registration for EM Segmenter
Wednesday, June 22, 2011, 3-4pm, Star room.
Synopsis:
The EM segmenter includes as a vital step the co-registration of a multiple subject atlas to obtain spatial priors for small region detection. The success of these priors depends heavily on the quality of the registration obtained. Because the registration includes a large-DOF nonrigid inter-subject registration, benchmarks for a good solution are largely absent. We seek an implementation of a registration using Slicer registration tools that will provide best possible robustness and if possible an estimate of reliability. Because this registration will be integrated into a slicer module, tools with a BSD license are strongly preferred.
Attendees (tentative):
- Kilian Pohl
- Dominik Meier
- Dominique Belhachemi
- Stephen Aylward
- Hans Johnson
- Bill Lorensen
- Jim Miller
- Allen Tannenbaum
- Daniel Haehn
Reference Material:
Preliminary Agenda:
- Description of the registration task for the EM segmenter
- Review of example case
- Comparison of BRAINSfit and CMTK strategies
- Discussion of design/implementation options/strategies
Meeting Notes:
- Hans pointed out that an upcoming fix, soon to be in ITK4, will incorporate an improved placement of control points, which reduces the need for masking
- CMTK takes ~1hr and is not a BSD license
- skull stripped input is not necessarily avail. for all input
- concatenation of multiple nonrigid transforms is also forthcoming in ITK4
- Plastimatch was not designed for brain MRI, but it does have multiresolution
- 2 track approach, using multiple versions that use different registration methods
- NA-MIC sandbox options: Andryi
- bootstrapping of transforms for saving time