Difference between revisions of "2012 Winter Project Week:SlidingOrgans"
From NAMIC Wiki
(Created page with '__NOTOC__ <gallery> Image:PW-SLC2012.png|Projects List Image:MP_RAGE_PRECONTRAST.png|An example T1 weighted image from a patient with TBI…') |
|||
Line 2: | Line 2: | ||
<gallery> | <gallery> | ||
Image:PW-SLC2012.png|[[2012_Winter_Project_Week#Projects|Projects List]] | Image:PW-SLC2012.png|[[2012_Winter_Project_Week#Projects|Projects List]] | ||
− | |||
</gallery> | </gallery> | ||
Line 16: | Line 15: | ||
<h3>Objective</h3> | <h3>Objective</h3> | ||
− | + | * Conventional deformable image registration enforces smooth motion, causing inaccurate displacement measurements near sliding motion. | |
+ | * Sliding motion is common in intra-subject 4D image registration problems, for example respiration-induced sliding of the lungs and abdominal organs against the chest wall. | ||
+ | * We have developed an image registration algorithm based on anisotropic diffusion that handles sliding motion. | ||
</div> | </div> | ||
Line 22: | Line 23: | ||
<h3>Approach, Plan</h3> | <h3>Approach, Plan</h3> | ||
− | * | + | * Continue algorithm validation experiments in 4D chest CT. |
− | + | * Improve CLI documentation and user interface. | |
+ | * Fix user experience issues of integration of TubeTK CLIs into Slicer 4. | ||
</div> | </div> |
Revision as of 07:21, 9 January 2012
Home < 2012 Winter Project Week:SlidingOrgansRegistration in the presence of sliding between organs
Key Investigators
- Kitware: Danielle Pace, Stephen Aylward
- UNC: Marc Niethammer
Objective
- Conventional deformable image registration enforces smooth motion, causing inaccurate displacement measurements near sliding motion.
- Sliding motion is common in intra-subject 4D image registration problems, for example respiration-induced sliding of the lungs and abdominal organs against the chest wall.
- We have developed an image registration algorithm based on anisotropic diffusion that handles sliding motion.
Approach, Plan
- Continue algorithm validation experiments in 4D chest CT.
- Improve CLI documentation and user interface.
- Fix user experience issues of integration of TubeTK CLIs into Slicer 4.
Progress
Delivery Mechanism
This work will be delivered to the NA-MIC Kit as a Slicer extension as a CLI distributed in TubeTK (http://public.kitware.com/Wiki/TubeTK)