Data Structure

Data structure consists of 144 Analyze image volumes. Vector onsets for task are in a text file included with each subject's data set.

Scan Parameters

Acquisition Plane:sagittal

Slice Thickness:5 mm (No Skip)

Number of Slices:29

TR:2500 ms

TE:40 ms

FOV:24 cm

NEX:1

Scan Matrix:64 x 64

Image Matrix:64 x 64

Repetitions:144