Common GET_LIST message ?

A common GET_LIST message could be defined with the data type, like IMAGE, in the device name field. The answer could be a LIST message with ids (each 20 bytes, so they can be used as device names) of available data. Afterwards a GET_xy message with the id could be used to query the details.

Well, I don't think this will help much in practice.

Example: an application wants to show a list of available images before querying them from the server. Ids are not very specific, so an additional meta data message must be defined. So we have a) GET_LIST and b) for each id: GET_IMGMETA. It would be easier to get all the meta data at once.

Next example: all ficucial points shall be queried. A two-step mechanism would result in 1+n queries, whereas getting all points at once would end in only 1 query. Even if the user would like to get only 1 specific point, how could he know which Id to use?

Another reason is that sending all the data at once is much more efficient.

However, there might be use cases, where single items are useful. If the item size is constant, it makes no difference if only one or several items are transmitted. The number is bodySize/itemSize. Using this definion, single items can still be pushed over the network as it's currently done in most OpenIGTLink applications.

Comments

I agree that generalized GET_LIST message is not necessary in many case. I would suggest to design GET_IMGMETA to allow requesting either list of metadata or metadata for a specific image. If there is a way to request meta data for a specific image, we can provide two-step approach (GET_LIST->GET_IMGMETA) in the future.

GET messages

Get messages are not well defined yet. The following things should be fixed:

* If 0 items are available, the bodysize of the answer is 0.
* If an error occurs while processing the request, a STATUS message shall be returned.

Comments

The STATUS message defines status code 4 "Not found (file, configuration, device etc)", which can be used to tell 0 items are available. The problem is that it is not possible to specify the device type in the STATUS message. The requesting host (the host that issues GET_* message) may not be able to identify which GET_* message is associated with the received STATUS message, because the OpenIGTLink message allows having different devices with the same device name. One possible solution is to use "Status name" field in STATUS message for specifying device name. For example:

  • Host A requests image (device type: "IMAGE", device name: "diffusion 1") to host B by sending GET_IMAGE message.
  • Host B receives the GET_IMAGE message, but it does not have such image.
  • Host B sends STATUS message with device type "STATUS", device name "diffusion 1", status code 4, and status message "NO IMAGE".

Fortunately, maximum length of the status name field is 20, longer than the maximum length of device name.

Image data

I would like to introduce a GET_IMGMETA message. This get-message has no parameters. The answer is IMGMETA:

Data Type Description
Name char[64] Pretty name of the image
Id char[20] Id to query the IMAGE and COLORT
Modality char[32] String which specifies the modality
Patient name char[64] Name of the patient
Patient id char[64] Id of the patient
Day 8 bit unsigned Scan day
Month 8 bit unsigned Scan month
Year 16 bit unsigned Scan year
RI, RJ, RK 16 bit unsigned Number of pixels in each direction (same as in IMAGE)
S 8 bit unsigned Scalar type (e.g. 3:uint8, 5:uint16, same as in IMAGE)
* More than one item can be transmitted. The number is bodySize/itemSize.
* To get the IMAGE, GET_IMAGE is used with the Id in the device name field.
* To get the COLORTABLE, GET_COLORT is used with the Id in the device name field. See Standard OpenIGTLink Protocol description -- Version 2 draft for details.

Comments

  • I would define time stamp as 64 bit unsigned int so that we can also specify time. (this is also used in the OpenIGTLink header. see OpenIGTLink/Timestamp.)
  • If a device name is specified in GET_IMGMETA, only one set of meta data for the image with specified device name is returned. (This allows two-step approach (GET_LIST->GET_IMGMETA), while supporting multiple sets of meta data in a single IMGMETA message.)
  • I would call the first field "Image description"

Point or fiducal data

Currently only transformations can be sent with OpenIGTLink, but especially points like fiducals or trajectories consist of more than a transformation.

GET_POINT is used to get all the point data. It has no parameters. The answer is a POINT message:

Data Type Description
Name char[64] Pretty name of the point data like "Fiducal behind left ear"
Group name char[32] Can be "Labeled Point", "Landmark", "Fiducal", "Trajectory", ...
Type 8 bit unsigned 1: single point, 2: trajectory with only entry point, 4: trajectory with only target point, 6: trajectory with entry and target point
R,G,B,A 8 bit unsigned Color in RGBA
X1,Y1,Z1 32 bit float Coordinate of the single point or entry point of the trajectory (which consists of an entry and a target point)
X2,Y2,Z2 32 bit float Target point of a trajectory. If the trajectory has length 0, it is equal to the entry point. For single points the coordinates are 0,0,0
Diameter 32 bit float Always 0 for single points, can be 0 for trajectories.
Owner image char[20] Id of the owner image/sliceset. Points from different slicesets can be sent if slicesets are fused.
* More than one item can be transmitted. The number is bodySize/itemSize.

Comments

  • For diameter, I think It's OK to allow value greater than 0 for single point.
  • Do we really need group name?
  • Is it possible to have TRAJECTORY type independently? I know POINTS and TRAJECTORY are very similar, but a bit confusing for those who new to the protocol.

Start / stop push

Currently there is no way to start or stop a pushing request. The message START_PUSH and STOP_PUSH shall be used for that purpose. The device name field shall contain the data type to be pushed. Everytime this data changes, new messages shall be sent until the pushing is stopped. The body of START_PUSH and STOP_PUSH can contain data specific arguments.

Comments

  • possible fields in START_PUSH message:
    • device type (TRACKINGDATA, TRANSFORM, IMAGE)
    • maximum time resolution (Hz)

Tracking data

In version 1 of the protocol, transformation matrices can be transmitted. But there are some additional requirements.

  • Specifing that something is not valid/visible anymore (could be done by 0-matrix)
  • Specifing which data is taken at the same time / part of the same camera frame (can be done with the timestamp field of the header)
  • Specifing the type of data, e.g. instrument, instrument without a direction, tracker, ... (could be done by a meta-data query)
  • Sending all tracking data each frame, e.g. 5 instruments/trackers at 60 Hz result in 300 message per second, which is very much. This should be reduced.

All the points above can be handles with a new message, let's call it TRACKINGDATA:

Data Type Description
Name char[20] Name (=Id) of the instrument/tracker
Type 8 bit unsigned 1: tracker, 2: instrument with tip and handle, 3: instrument only with tip defined
Matrix 32 bit float 12 values like in TRANSFORM message
* All tracking data from one frame is included.
* Invisible/unavailable trackers/instruments are not included.
* Easy to develop. Sample pseudo code: while(true) { recv(trackingdata); updateView(trackingdata); }

This message cannot be queried with a regular GET message, but with START_PUSH and STOP_PUSH messages. The device name field consists of the string "TRACKINGDATA".

Usually the tracking data will be sent using the standard coordinate system, which is also used for POINT, IMAGE, ... But this does only work after patient registration. Therefore the body of START_PUSH has an optional field for specifing the coordinate system "CAMERA". To switch back to the standard coordinate system, one has to send STOP_PUSH and afterwards START_PUSH without explicitly specifing the camera coordinate system.

Comments

  • How about adding 8- or 16-bit status field in TRACKINGDATA? This will allow us to indicate that coordinate system is not registered. I would like to keep START_PUSH message simple....