=functions=
 
=functions=
 
# Interface
 
# Interface
## Generated a separate image rendering window to display captured endoscope view
+
## ''Generate a separate image rendering window to display captured endoscope view''
## Make module with four pages
+
## ''Make module with four pages''
 
# Display page
 
# Display page
## size of the windows
+
## ''size of the windows''
## show/hide them
+
## ''show/hide them''
 
# Registration page
 
# Registration page
 
## interfaces for ICP registration
 
## interfaces for ICP registration
Line 11: Line 11:
 
### using tracker (currently using NaviTrack, but IGSTK is preferable)
 
### using tracker (currently using NaviTrack, but IGSTK is preferable)
 
### i/f to give good intial guess
 
### i/f to give good intial guess
### i/f to foot switch  
+
### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)
 
# Camera page
 
# Camera page
 
## Color Subframe  
 
## Color Subframe  
### changing  color of the camera
+
### ''changing  color of the camera''
 
## Shape Subframe
 
## Shape Subframe
### changing the Focal Point
+
### ''show/hide Focal Point''
### change size of the camera
+
### ''change size of the camera''
### 3D Gyro on/off switch
+
### ''3D Gyro on/off switch''
### Size changing of the Gyro
+
### ''Size changing of the Gyro''
 +
### ''different camera shapes''
 
## Probe Subframe
 
## Probe Subframe
### show/hide Sensor/Locator
+
### ''show/hide Sensor/Locator''
 
### show/hide Probe  
 
### show/hide Probe  
 
### show/hide guide (pointing tool (double length of Sensor/Locator)
 
### show/hide guide (pointing tool (double length of Sensor/Locator)
Line 27: Line 28:
 
## View
 
## View
 
### Set Lens Angle (related to the real endoscope lens angle)
 
### Set Lens Angle (related to the real endoscope lens angle)
### control graphics and real endoscope ()
+
### control graphics and real endoscope
### lock camera to the sensor, probe of the tracking device or Free view
+
### ''lock camera to the sensor, probe of the tracking device or Free view''
 
### camera calibration of different views of the endoscope camera
 
### camera calibration of different views of the endoscope camera
 
#### Transform fisheye view to normal view
 
#### Transform fisheye view to normal view
### flat colon screen (optional)
+
### ''flat colon screen (optional)''
 
# Navigation
 
# Navigation
## view point control
+
## ''view point control''
## absolut and relative orientation and navigation of the camera
+
## ''absolut and relative orientation and navigation of the camera''
 
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up
 
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up
 
### Points in higher/lower slides appear
 
### Points in higher/lower slides appear

Revision as of 20:47, 22 June 2007

Home < Neuroendoscope-igt

functions

  1. Interface
    1. Generate a separate image rendering window to display captured endoscope view
    2. Make module with four pages
  2. Display page
    1. size of the windows
    2. show/hide them
  3. Registration page
    1. interfaces for ICP registration
      1. i/f to select partical surface for ICP (optional)
      2. using tracker (currently using NaviTrack, but IGSTK is preferable)
      3. i/f to give good intial guess
      4. i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)
  4. Camera page
    1. Color Subframe
      1. changing color of the camera
    2. Shape Subframe
      1. show/hide Focal Point
      2. change size of the camera
      3. 3D Gyro on/off switch
      4. Size changing of the Gyro
      5. different camera shapes
    3. Probe Subframe
      1. show/hide Sensor/Locator
      2. show/hide Probe
      3. show/hide guide (pointing tool (double length of Sensor/Locator)
      4. virtual ruler (in 0.1 cm steps) changeable by slider
    4. View
      1. Set Lens Angle (related to the real endoscope lens angle)
      2. control graphics and real endoscope
      3. lock camera to the sensor, probe of the tracking device or Free view
      4. camera calibration of different views of the endoscope camera
        1. Transform fisheye view to normal view
      5. flat colon screen (optional)
  5. Navigation
    1. view point control
    2. absolut and relative orientation and navigation of the camera
    3. Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up
      1. Points in higher/lower slides appear
      2. cleanup function for all points/certain points
    4. fiducials creation
      1. related to a selected model
  6. Aditional features
    1. freeze/pause slicer display
      1. no changes are possible
      2. save the current scene
    2. alarm function
      1. by an unstable magneticfield Alarm will occur