Difference between revisions of "Projects:RegistrationDocumentation:UseCaseInventory:BrainIntraDTI"

From NAMIC Wiki
Jump to: navigation, search
 
(25 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
[[Projects:RegistrationDocumentation:UseCaseInventory|back to Library Main Page]]  <br>
 
==Case Inventory DTI ==
 
==Case Inventory DTI ==
*Intra-subject T1-T2-DTI-fMRI
+
The most common task in Diffusion MRI registration is aligning an anatomical reference with the tensor data or fiber-tracts derived from DTI. Because the DTI is tensor data, applying a spatial transform to this image is not trivial. Hence a common approach is to align the anatomical reference (such as a T1 MRI) to the DTI image and thus avoid having to resample the tensor. This, however, preserves the strong distortions often present in the DTI image and makes anatomical referencing difficult.
*Intra-subject T1-T2-DTI
+
 
**DTI baseline to T1 inter-subject with clipped FOV
+
*[[Image:RegLib_C03_Baseline_axial.png|70px|lleft|RegLib 03: DTI alignment]] [[Image:RegLib_C03_DTIVol_axial.png|70px|lleft|RegLib C03: DTI alignment]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]]  '''Case 03: [[Projects:RegistrationLibrary:RegLib_C03|DWI alignment: align DTI volume with T2 structural reference scan]]'''
**[[DTI-non-rigid|DTI affine & non-rigid alignment]]
+
*[[Image:RegLib_C03_Baseline_axial.png|70px|lleft|RegLib 03: DTI alignment]] [[Image:RegLib_C03_DTIVol_axial.png|70px|lleft|RegLib C03: DTI alignment]]  Case 03B: [[Projects:RegistrationLibrary:RegLib_C03B|DWI alignment + '''preprocessing''']]
 +
*[[Image:RegLib27_FLAIR.png|70px|lleft|RegLib C27 FLAIR]] [[Image:RegLib27_DTI.png|70px|lleft|RegLib C27 DTI]]  [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]]  '''Case 27: [[Projects:RegistrationLibrary:RegLib_C27|DTI baseline to FLAIR/T1 pair, large pathol.]]'''
 +
*[[Image:RegLib_C29_Thumb.png|140px|lleft|RegLib C29]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 29: [[Projects:RegistrationLibrary:RegLib_C29|DTI to T1]] ''' / <small> Alignment of DTI and fMRI scan to structural reference T2/T1 pair for surgical planning (tumor resection)</small>
 +
*[[Image:RegLib_C30_Thumb1.png|70px|lleft|RegLib C30 fixed]] [[Image:RegLib_C30_Thumb2.png|70px|lleft|RegLib C30 moving]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]]  '''Case 30: [[Projects:RegistrationLibrary:RegLib_C30|lowres & small FOV DTI  to T1, no T2]]'''
 +
* [[Image:RegLib_C30_Thumb2.png|70px|lleft|RegLib C30 moving]][[Image:RegLib_C30_Thumb1.png|70px|lleft|RegLib C30 fixed]]  [[Image:Slicer3-6Announcement-v1.png‎|70px|This case is complete and up to date for version 3.6.1]]'''Case 32: [[Projects:RegistrationLibrary:RegLib_C32| inverse direction: T1 to DTI ]]'''
 +
*[[Image:RegLib_C33_Thumb1.png|70px|lleft|RegLib C33 SPGR]] [[Image:RegLib_C33_Thumb4.png|70px|lleft|RegLib C33 DTI]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]]  '''Case 33: [[Projects:RegistrationLibrary:RegLib_C33|DTI baseline to T1, incl. pathol.]]'''
 +
 
 +
<!--
 +
 
 +
*[[Image:NAMIC logo.png|70px|lleft|RegLib Thumbnail placeholder]] [[Image:NAMIC logo.png|70px|lleft|RegLib Thumbnail placeholder]] Case ??: DTI baseline to T1 inter-subject with clipped FOV
 +
 
 +
-->

Latest revision as of 20:19, 16 May 2012

Home < Projects:RegistrationDocumentation:UseCaseInventory:BrainIntraDTI

back to Library Main Page

Case Inventory DTI

The most common task in Diffusion MRI registration is aligning an anatomical reference with the tensor data or fiber-tracts derived from DTI. Because the DTI is tensor data, applying a spatial transform to this image is not trivial. Hence a common approach is to align the anatomical reference (such as a T1 MRI) to the DTI image and thus avoid having to resample the tensor. This, however, preserves the strong distortions often present in the DTI image and makes anatomical referencing difficult.