Difference between revisions of "2008 Summer Project Week:DWIRegistrationOMT"
From NAMIC Wiki
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{| | {| | ||
|[[Image:ProjectWeek-2008.png|thumb|320px|Return to [[2008_Summer_Project_Week|Project Week Main Page]] ]] | |[[Image:ProjectWeek-2008.png|thumb|320px|Return to [[2008_Summer_Project_Week|Project Week Main Page]] ]] | ||
− | |[[Image:Dwi_image_1.jpg | OMT Deformation Grid | 300px ]] | + | |[[Image:Dwi_image_1.jpg | thumb | 300px | OMT Deformation Grid on MRI ]] |
+ | |[[Image:Dwi_image_2.jpg | thumb | 300px | OMT Deformation Grid on DWI ]] | ||
|} | |} | ||
+ | |||
__NOTOC__ | __NOTOC__ | ||
Line 34: | Line 36: | ||
<h1>Progress</h1> | <h1>Progress</h1> | ||
* Currently the algorithm and registration framework is available in MATLAB | * Currently the algorithm and registration framework is available in MATLAB | ||
− | * Preliminary results with DWI baseline image correction | + | * Preliminary results with DWI baseline image correction. |
+ | * DWI and MRI image intensity normalization using CSF and White-Matter/Grey-Matter segmentations performed to make sure both image volumes are on same footing so that Mass Transport mapping is found without introducing structural distortions. | ||
+ | * Further experiments required to fine tune the normalization step. | ||
+ | * Slicer command line module created for interfacing with OMT Registration algorithm. A few issues with nrrd files being resolved. | ||
+ | * Discussions with Core 2 on existing infrastructure within ITK for non-rigid registration and re-use of demons diffeomorphic registration filter framework for OMT Registration filter. | ||
+ | |||
</div> | </div> | ||
Latest revision as of 13:30, 27 June 2008
Home < 2008 Summer Project Week:DWIRegistrationOMT
Key Investigators
- Allen Tannenbaum, Tauseef ur Rehman, John Melonakos (Georgia Tech)
- Marek Kubicki, Sylvain Bouix (BWH)
Objective
- To explore the portability of Optimal Mass Transport (OMT) Non-rigid Registration code to the NAMIC toolkit.
- To determine applicability of OMT registration algorithm for DWI Distortion Correction.
Approach, Plan
- Conversations with Core 2 to analyze the project
- Discussions with Core 3 to see how to adapt the existing code for DWI Registration
- Make a project plan
Progress
- Currently the algorithm and registration framework is available in MATLAB
- Preliminary results with DWI baseline image correction.
- DWI and MRI image intensity normalization using CSF and White-Matter/Grey-Matter segmentations performed to make sure both image volumes are on same footing so that Mass Transport mapping is found without introducing structural distortions.
- Further experiments required to fine tune the normalization step.
- Slicer command line module created for interfacing with OMT Registration algorithm. A few issues with nrrd files being resolved.
- Discussions with Core 2 on existing infrastructure within ITK for non-rigid registration and re-use of demons diffeomorphic registration filter framework for OMT Registration filter.