Difference between revisions of "Projects:RegistrationDocumentation:UseCaseInventory:BrainIntraDTI"
From NAMIC Wiki
(Created page with '*Intra-subject T1-T2-DTI-fMRI *Intra-subject T1-T2-DTI **DTI baseline to T1 inter-subject with clipped FOV **DTI affine & non-rigid alignment') |
|||
(26 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | [[Projects:RegistrationDocumentation:UseCaseInventory|back to Library Main Page]] <br> | |
− | * | + | ==Case Inventory DTI == |
− | **DTI baseline to T1 inter-subject with clipped FOV | + | The most common task in Diffusion MRI registration is aligning an anatomical reference with the tensor data or fiber-tracts derived from DTI. Because the DTI is tensor data, applying a spatial transform to this image is not trivial. Hence a common approach is to align the anatomical reference (such as a T1 MRI) to the DTI image and thus avoid having to resample the tensor. This, however, preserves the strong distortions often present in the DTI image and makes anatomical referencing difficult. |
− | + | ||
+ | *[[Image:RegLib_C03_Baseline_axial.png|70px|lleft|RegLib 03: DTI alignment]] [[Image:RegLib_C03_DTIVol_axial.png|70px|lleft|RegLib C03: DTI alignment]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 03: [[Projects:RegistrationLibrary:RegLib_C03|DWI alignment: align DTI volume with T2 structural reference scan]]''' | ||
+ | *[[Image:RegLib_C03_Baseline_axial.png|70px|lleft|RegLib 03: DTI alignment]] [[Image:RegLib_C03_DTIVol_axial.png|70px|lleft|RegLib C03: DTI alignment]] Case 03B: [[Projects:RegistrationLibrary:RegLib_C03B|DWI alignment + '''preprocessing''']] | ||
+ | *[[Image:RegLib27_FLAIR.png|70px|lleft|RegLib C27 FLAIR]] [[Image:RegLib27_DTI.png|70px|lleft|RegLib C27 DTI]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 27: [[Projects:RegistrationLibrary:RegLib_C27|DTI baseline to FLAIR/T1 pair, large pathol.]]''' | ||
+ | *[[Image:RegLib_C29_Thumb.png|140px|lleft|RegLib C29]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 29: [[Projects:RegistrationLibrary:RegLib_C29|DTI to T1]] ''' / <small> Alignment of DTI and fMRI scan to structural reference T2/T1 pair for surgical planning (tumor resection)</small> | ||
+ | *[[Image:RegLib_C30_Thumb1.png|70px|lleft|RegLib C30 fixed]] [[Image:RegLib_C30_Thumb2.png|70px|lleft|RegLib C30 moving]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 30: [[Projects:RegistrationLibrary:RegLib_C30|lowres & small FOV DTI to T1, no T2]]''' | ||
+ | * [[Image:RegLib_C30_Thumb2.png|70px|lleft|RegLib C30 moving]][[Image:RegLib_C30_Thumb1.png|70px|lleft|RegLib C30 fixed]] [[Image:Slicer3-6Announcement-v1.png|70px|This case is complete and up to date for version 3.6.1]]'''Case 32: [[Projects:RegistrationLibrary:RegLib_C32| inverse direction: T1 to DTI ]]''' | ||
+ | *[[Image:RegLib_C33_Thumb1.png|70px|lleft|RegLib C33 SPGR]] [[Image:RegLib_C33_Thumb4.png|70px|lleft|RegLib C33 DTI]] [[Image:Slicer41VerifiedIcon.png|50px|verified/updated for Slicer 4.1]] '''Case 33: [[Projects:RegistrationLibrary:RegLib_C33|DTI baseline to T1, incl. pathol.]]''' | ||
+ | |||
+ | <!-- | ||
+ | |||
+ | *[[Image:NAMIC logo.png|70px|lleft|RegLib Thumbnail placeholder]] [[Image:NAMIC logo.png|70px|lleft|RegLib Thumbnail placeholder]] Case ??: DTI baseline to T1 inter-subject with clipped FOV | ||
+ | |||
+ | --> |
Latest revision as of 20:19, 16 May 2012
Home < Projects:RegistrationDocumentation:UseCaseInventory:BrainIntraDTICase Inventory DTI
The most common task in Diffusion MRI registration is aligning an anatomical reference with the tensor data or fiber-tracts derived from DTI. Because the DTI is tensor data, applying a spatial transform to this image is not trivial. Hence a common approach is to align the anatomical reference (such as a T1 MRI) to the DTI image and thus avoid having to resample the tensor. This, however, preserves the strong distortions often present in the DTI image and makes anatomical referencing difficult.
- Case 03: DWI alignment: align DTI volume with T2 structural reference scan
- Case 03B: DWI alignment + preprocessing
- Case 27: DTI baseline to FLAIR/T1 pair, large pathol.
- Case 29: DTI to T1 / Alignment of DTI and fMRI scan to structural reference T2/T1 pair for surgical planning (tumor resection)
- Case 30: lowres & small FOV DTI to T1, no T2
- Case 32: inverse direction: T1 to DTI
- Case 33: DTI baseline to T1, incl. pathol.