This module implements a local intensity correction for inhomogeneities due to coil placement in Cardiac LGE-MRI images.  It fits a gradient function to the image data an normalizes accordingly.  Note that this is not a whole image correction and it is specific to LGE MRI Cardiac images.  The input to this module is a segmented region on which to base the intensity gradient model.  There are no parameters.
+
===CMR Toolkit Inhomogeneity Correction Filter===
 +
 
 +
{|
 +
|[[Image:carma_afib_inhomogeneity_correction.png|thumb|280px|Inhomogeneity correction, original above, corrected below]]
 +
|}
 +
 
 +
==Authors, Collaborators & Contact==
 +
* CARMA Center, University of Utah: Alan Morris, Eugene Kholmovski, Josh Cates, Rob MacLeod
 +
 
 +
<div style="margin: 20px;">
 +
<div style="width: 27%; float: left; padding-right: 3%;">
 +
 
 +
==General Information==
 +
===Module Type & Category===
 +
 
 +
Type: CLI
 +
 
 +
Category: Cardiac MRI Toolkit
 +
 
 +
</div>
 +
 
 +
<div style="width: 27%; float: left; padding-right: 3%;">
 +
 
 +
==Module Description==
 +
This module implements a local intensity correction for inhomogeneities due to coil placement in cardiac LGE-MRI images.  It fits a gradient function to the image data and normalizes accordingly.  Note that this is not a whole image correction and it is specific to LGE MRI cardiac images.  The input to this module is a segmented region on which to base the intensity gradient model and a segmentation of the region of interest to apply the correction.  There are no parameters.
 +
 
 +
</div>
 +
 
 +
<div style="width: 40%; float: left;">
 +
 
 +
== Usage ==
 +
 
 +
===Examples, Use Cases & Tutorials===
 +
 
 +
* This module is meant to be used for MRI scans where local inhomogeneity has been detected
 +
* [[Media:CARMA_Inhomogeneity_correction_filter_tutorial.pptx|CARMA Automatic Cardiac MRI Inhomogeneity Correction Filter Tutorial]]
 +
 
 +
===Quick Tour of Features and Use===
 +
 
 +
The following are the inputs and outputs
 +
 
 +
* MRI Image : Select the DE-MRI image
 +
* Blood Pool mask : Select the label map for the blood pool
 +
* ROI mask : Select the label map for the targeted region of interest
 +
* Corrected Output : The output volume
 +
 
 +
</div>
 +
</div>
 +
 
 +
<div style="margin: 20px;">
 +
<div style="width: 27%; float: left; padding-right: 3%;">
 +
 
 +
== Development ==
 +
 
 +
===Source Code & Documentation===
 +
 
 +
The source code for this module can be found at the [https://github.com/carma-center/carma_slicer_extension/ GitHub repository].
 +
 
 +
</div>
 +
 
 +
<div style="width: 27%; float: left; padding-right: 3%;">

Latest revision as of 19:54, 29 July 2013

Home < DBP3:Utah:SlicerModuleInhomogeneity

CMR Toolkit Inhomogeneity Correction Filter

Inhomogeneity correction, original above, corrected below

Authors, Collaborators & Contact

  • CARMA Center, University of Utah: Alan Morris, Eugene Kholmovski, Josh Cates, Rob MacLeod

General Information

Module Type & Category

Type: CLI

Category: Cardiac MRI Toolkit

Module Description

This module implements a local intensity correction for inhomogeneities due to coil placement in cardiac LGE-MRI images. It fits a gradient function to the image data and normalizes accordingly. Note that this is not a whole image correction and it is specific to LGE MRI cardiac images. The input to this module is a segmented region on which to base the intensity gradient model and a segmentation of the region of interest to apply the correction. There are no parameters.

Usage

Examples, Use Cases & Tutorials

Quick Tour of Features and Use

The following are the inputs and outputs

  • MRI Image : Select the DE-MRI image
  • Blood Pool mask : Select the label map for the blood pool
  • ROI mask : Select the label map for the targeted region of interest
  • Corrected Output : The output volume