Difference between revisions of "DBP3:Utah:SlicerModuleInhomogeneity"

From NAMIC Wiki
Jump to: navigation, search
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
__NOTOC__
 
__NOTOC__
===CARMA Inhomogeneity Correction Filter===
+
===CMR Toolkit Inhomogeneity Correction Filter===
  
 
{|
 
{|
Line 17: Line 17:
 
Type: CLI
 
Type: CLI
  
Category: CARMA
+
Category: Cardiac MRI Toolkit
  
 
</div>
 
</div>
Line 54: Line 54:
 
== Development ==
 
== Development ==
  
===Known bugs===
+
===Source Code & Documentation===
  
Follow this [http://na-mic.org/Mantis/main_page.php link] to the Slicer bug tracker.
+
The source code for this module can be found at the [https://github.com/carma-center/carma_slicer_extension/ GitHub repository].
 
 
===Usability issues===
 
 
 
Follow this [http://na-mic.org/Mantis/main_page.php link] to the Slicer bug tracker. Please select the '''usability issue category''' when browsing or contributing.
 
 
 
===Source code & documentation===
 
 
 
Customize following [http://www.na-mic.org/ViewVC/index.cgi/ links] for your module.
 
 
 
[http://www.na-mic.org/Slicer/Documentation/Slicer3/html/ Links] to documentation generated by doxygen.
 
  
 
</div>
 
</div>
  
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
<div style="width: 27%; float: left; padding-right: 3%;">
 
== More Information ==
 
 
===Acknowledgment===
 
Include funding and other support here.
 
 
===References===
 
Publications related to this module go here. Links to pdfs would be useful.
 
 
</div>
 
</div>
 

Latest revision as of 19:54, 29 July 2013

Home < DBP3:Utah:SlicerModuleInhomogeneity

CMR Toolkit Inhomogeneity Correction Filter

Inhomogeneity correction, original above, corrected below

Authors, Collaborators & Contact

  • CARMA Center, University of Utah: Alan Morris, Eugene Kholmovski, Josh Cates, Rob MacLeod

General Information

Module Type & Category

Type: CLI

Category: Cardiac MRI Toolkit

Module Description

This module implements a local intensity correction for inhomogeneities due to coil placement in cardiac LGE-MRI images. It fits a gradient function to the image data and normalizes accordingly. Note that this is not a whole image correction and it is specific to LGE MRI cardiac images. The input to this module is a segmented region on which to base the intensity gradient model and a segmentation of the region of interest to apply the correction. There are no parameters.

Usage

Examples, Use Cases & Tutorials

Quick Tour of Features and Use

The following are the inputs and outputs

  • MRI Image : Select the DE-MRI image
  • Blood Pool mask : Select the label map for the blood pool
  • ROI mask : Select the label map for the targeted region of interest
  • Corrected Output : The output volume

Development

Source Code & Documentation

The source code for this module can be found at the GitHub repository.