Difference between revisions of "Neuroendoscope-igt"
From NAMIC Wiki
Line 1: | Line 1: | ||
=functions= | =functions= | ||
# Interface | # Interface | ||
− | ## | + | ## ''Generate a separate image rendering window to display captured endoscope view'' |
− | ## Make module with four pages | + | ## ''Make module with four pages'' |
# Display page | # Display page | ||
− | ## size of the windows | + | ## ''size of the windows'' |
− | ## show/hide them | + | ## ''show/hide them'' |
# Registration page | # Registration page | ||
## interfaces for ICP registration | ## interfaces for ICP registration | ||
Line 11: | Line 11: | ||
### using tracker (currently using NaviTrack, but IGSTK is preferable) | ### using tracker (currently using NaviTrack, but IGSTK is preferable) | ||
### i/f to give good intial guess | ### i/f to give good intial guess | ||
− | ### i/f to foot switch | + | ### i/f to foot switch (currently using NaviTrack, but IGSTK is preferable) |
# Camera page | # Camera page | ||
## Color Subframe | ## Color Subframe | ||
− | ### changing color of the camera | + | ### ''changing color of the camera'' |
## Shape Subframe | ## Shape Subframe | ||
− | ### | + | ### ''show/hide Focal Point'' |
− | ### change size of the camera | + | ### ''change size of the camera'' |
− | ### 3D Gyro on/off switch | + | ### ''3D Gyro on/off switch'' |
− | ### Size changing of the Gyro | + | ### ''Size changing of the Gyro'' |
+ | ### ''different camera shapes'' | ||
## Probe Subframe | ## Probe Subframe | ||
− | ### show/hide Sensor/Locator | + | ### ''show/hide Sensor/Locator'' |
### show/hide Probe | ### show/hide Probe | ||
### show/hide guide (pointing tool (double length of Sensor/Locator) | ### show/hide guide (pointing tool (double length of Sensor/Locator) | ||
Line 27: | Line 28: | ||
## View | ## View | ||
### Set Lens Angle (related to the real endoscope lens angle) | ### Set Lens Angle (related to the real endoscope lens angle) | ||
− | ### control graphics and real endoscope | + | ### control graphics and real endoscope |
− | ### lock camera to the sensor, probe of the tracking device or Free view | + | ### ''lock camera to the sensor, probe of the tracking device or Free view'' |
### camera calibration of different views of the endoscope camera | ### camera calibration of different views of the endoscope camera | ||
#### Transform fisheye view to normal view | #### Transform fisheye view to normal view | ||
− | ### flat colon screen (optional) | + | ### ''flat colon screen (optional)'' |
# Navigation | # Navigation | ||
− | ## view point control | + | ## ''view point control'' |
− | ## absolut and relative orientation and navigation of the camera | + | ## ''absolut and relative orientation and navigation of the camera'' |
## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up | ## Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up | ||
### Points in higher/lower slides appear | ### Points in higher/lower slides appear |
Revision as of 20:47, 22 June 2007
Home < Neuroendoscope-igtfunctions
- Interface
- Generate a separate image rendering window to display captured endoscope view
- Make module with four pages
- Display page
- size of the windows
- show/hide them
- Registration page
- interfaces for ICP registration
- i/f to select partical surface for ICP (optional)
- using tracker (currently using NaviTrack, but IGSTK is preferable)
- i/f to give good intial guess
- i/f to foot switch (currently using NaviTrack, but IGSTK is preferable)
- interfaces for ICP registration
- Camera page
- Color Subframe
- changing color of the camera
- Shape Subframe
- show/hide Focal Point
- change size of the camera
- 3D Gyro on/off switch
- Size changing of the Gyro
- different camera shapes
- Probe Subframe
- show/hide Sensor/Locator
- show/hide Probe
- show/hide guide (pointing tool (double length of Sensor/Locator)
- virtual ruler (in 0.1 cm steps) changeable by slider
- View
- Set Lens Angle (related to the real endoscope lens angle)
- control graphics and real endoscope
- lock camera to the sensor, probe of the tracking device or Free view
- camera calibration of different views of the endoscope camera
- Transform fisheye view to normal view
- flat colon screen (optional)
- Color Subframe
- Navigation
- view point control
- absolut and relative orientation and navigation of the camera
- Set points in DICOM(2D viewer) at a certain position and slice, remain until clean up
- Points in higher/lower slides appear
- cleanup function for all points/certain points
- fiducials creation
- related to a selected model
- Aditional features
- freeze/pause slicer display
- no changes are possible
- save the current scene
- alarm function
- by an unstable magneticfield Alarm will occur
- freeze/pause slicer display