Difference between revisions of "Projects:RegistrationDocumentation:UseCaseList"
From NAMIC Wiki
(Created page with '---- ==Case Inventory Brain== *'''Case 01: Inter-subject Brain MRI (Tumor growth assessment): sagittal T1 with meningioma…') |
|||
Line 1: | Line 1: | ||
---- | ---- | ||
+ | [[Projects:RegistrationDocumentation:UseCaseInventory|back to Use Case Library]] <br> | ||
+ | [[Projects:RegistrationDocumentation|back to Registration Main Page]] | ||
==Case Inventory Brain== | ==Case Inventory Brain== |
Latest revision as of 21:55, 21 January 2010
Home < Projects:RegistrationDocumentation:UseCaseListback to Use Case Library
back to Registration Main Page
Contents
Case Inventory Brain
- Case 01: Inter-subject Brain MRI (Tumor growth assessment): sagittal T1 with meningioma
- Case 02: Intra-subject Brain MRI (Multiple Sclerosis): T2 FLAIR to (defaced) T1 SPGR
- Intra-subject T1-T2-DTI-fMRI
- Intra-subject T1-T2-DTI
- DTI baseline to T1 inter-subject with clipped FOV
- DTI affine & non-rigid alignment
- Intra-subject PD,T2, T1Gd (MS)
- Scan-rescan intra-subject. No change.
- UNC Midas Database of healthy volunteers
- fMRI: inter-subject structural scan to MNI atlas target
- cases with defacing applied with mask avail.
- cases with defacing w/o mask
- example of half-way registration: 2 sets
- BIRN dataset ELUDE: longitudinal study of late-life depression at Duke University. There are 281 depressed subjects and 154 controls included. An MR scan of each subject was obtained every 2 years for up to 8 years (total of 1093 scans). ELUDE link (XNAT)
- BIRN dataset MIRIAD: cross-sectional depression. MIRIAD link (XNAT)
- BIRN dataset OASIS (XNAT)
- AC-PC alignment: can I do this with Slicer? -> fiducial-based alignment as separate module
- Registration comparison w & w.o bias field correction. When it does make a difference.
- defacing algorithm: Hum Brain Mapp. 2007 Sep;28(9):892-903.
Case Inventory Non-Brain
- PET-CT whole body, 2 timepoints each -- see here
- breast Cancer MRI: pre- and post-treatment
- prostate image database (intra- and inter-subject registration use cases) http://prostatemrimagedatabase.com/index.html
- knee registration for Simbios project -- http://slicer.spl.harvard.edu/slicerWiki/index.php/Stanford_Simbios_group
- liver tumor ablation: pre-procedural MRI to intra-procedural CT --> Dr. Stuart Silverman's IGT group: manuscript
- kidney tumor ablation: pre-procedural MRI to intra-procedural CT --> Dr. Stuart Silverman's IGT group
- kidney tumor ablation: intra-procedural CT - CT
- liver CT, intra-subject, contrast enhanced manuscript
- temporal bone (ear) intra-subject CT to MRI of the collab with Soenke in 2005
- tibia CT, Model-based surface registration
Case Inventory Non-human
Self-validation Sets
These are datasets with artificial misalignment, i.e. the perfect alignment is known.
- testing PET-CT-MRI on the Vanderbuild database: RIRE
- Dual Echo PD/T2 intra subject different contrast self validation
- Isotropic Brain SPGR T1 with single axis rotation
- Parameter Sensitivity Analysis
First 10 cases (not in sequential order)
- Brain intra-subject, same contrast T1, change detection follow-up: tumor growth
- Brain MRI, intra-subject, same contrast PD&T2, change detection follow-up: new MS lesions
- Brain MRI, intra-subject, different contrast, co-register all series of the same exam: T1 SPGR, FLAIR, T2
- Brain MRI, intra-subject, DTI to reference, apply Xform to 25-direction DTI tensor
- Brain MRI, intra-subject, example with clipped FOV, example of masking required
- Brain MRI, inter-subject, co-register T1 SPGR to atlas dataset (ICBM). Resample a label map.
- Liver intra-subject, pre-procedural MRI to intra-procedural CT
- Prostate MRI, intra-subject
- Knee inter-subject registration to initialize segmentation
- PET to CT Whole Body single timepoint
- Breast Cancer: feasible with affine focus?