Difference between revisions of "Projects:RegistrationLibrary:RegLib C29"

From NAMIC Wiki
Jump to: navigation, search
Line 22: Line 22:
  
 
=== Modules ===
 
=== Modules ===
*'''Slicer 3.6.1 recommended modules:  [http://www.slicer.org/slicerWiki/index.php/Modules:BRAINSFit BrainsFit], [http://www.slicer.org/slicerWiki/index.php/Modules:RegisterImagesMultiRes-Documentation-3.6 Robust Multiresolution Affine]'''
+
*'''Slicer 3.6.1 recommended modules:  [http://www.slicer.org/slicerWiki/index.php/Modules:BRAINSFit BrainsFit]'''
  
 
===Objective / Background ===
 
===Objective / Background ===
Line 33: Line 33:
 
*reference/fixed : T1 SPGR , 0.5x0.5x1 mm voxel size, 512 x 512 x 176  
 
*reference/fixed : T1 SPGR , 0.5x0.5x1 mm voxel size, 512 x 512 x 176  
 
*moving 1: T2 0.5x0.5x1.5 mm voxel size, 512 x 512 x 92
 
*moving 1: T2 0.5x0.5x1.5 mm voxel size, 512 x 512 x 92
*moving 2: DTI  baseline: 1 x 1 x 3 mm, 256 x 256 x 41
+
*moving 2a: DTI  baseline: 1 x 1 x 3 mm, 256 x 256 x 41
 
*moving 2b: 1 x 1 x 3 mm, 256 x 256 x 41 x 9 (tensor), original: DWI 256 x 256 x 41 x 32 directions
 
*moving 2b: 1 x 1 x 3 mm, 256 x 256 x 41 x 9 (tensor), original: DWI 256 x 256 x 41 x 32 directions
  
Line 48: Line 48:
 
=== Procedures ===
 
=== Procedures ===
 
'''with  BrainsFit''' (ca. 3 min):
 
'''with  BrainsFit''' (ca. 3 min):
 +
*Part I: LOAD DATA
 
#download example dataset
 
#download example dataset
#load into 3DSlicer 3.6  
+
#load into 3DSlicer 3.6.1 (Load Scene)
 +
#To convert the DWI into a DTI: use the ''Converters / DICOM to NRRD Converter'' module
 +
*Part II:REGISTER DTI TO T2
 
#open Registration : ''BrainsFit'' module
 
#open Registration : ''BrainsFit'' module
#Input Parameters: set SPGR as fixed and FLAIR as moving image
+
##Registration Phases:  
#Registration Phases:
+
##set T2 as fixed and DTI_baseline as moving image
 +
##select/check ''Include Rigid registration phase''
 +
##select/check ''Include Affine registration phase''
 +
##select/check ''Include BSpline registration phase''
 
##select ''Initialize with CenterofHeadAlign''
 
##select ''Initialize with CenterofHeadAlign''
 
##select ''Include Rigid registration phase''
 
##select ''Include Rigid registration phase''
 
##select  "Include Affine registration phase"  
 
##select  "Include Affine registration phase"  
#Output Settings: select "New Linear Transform" under ''Output Transform''
+
#Output Settings:  
#accept all other defaults & click apply
+
##select a new transform "Slicer BSpline Transform" under ''Output Transform''
 +
##select a new volume "Output Image Volume''
 +
#Registration Parameters: increase ''Number Of Samples'' to 200,000
 +
#Leave all other settings at default
 +
#click apply; runtime ca. 3 min.
 +
 
 +
 
 
#program will automatically move FLAIR image  under the result transform; also manually move the labelmap
 
#program will automatically move FLAIR image  under the result transform; also manually move the labelmap
 
#right click on either image and select ''Harden Transform'' to apply & resample
 
#right click on either image and select ''Harden Transform'' to apply & resample

Revision as of 18:37, 30 August 2010

Home < Projects:RegistrationLibrary:RegLib C29

Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory

v3.6.1 Slicer3-6Announcement-v1.png Slicer Registration Library Case #29: Intra-subject Brain DTI

Input

this is the fixed reference image. All images are aligned into this space lleft this is the T2 reference image, serves as target to the DTI baseline, but is itself aligned to the SPGR lleft this is the DTI Baseline scan, to be registered with the T2 this is the DTI tensor image, in the same orientation as the DTI Baseline
fixed image/target moving image 1 moving image 2a moving image 2b

Modules

Objective / Background

This is a classic case of a multi-sequence MRI exam we wish to spatially align to the anatomical reference scan (T1-SPGR). The scan of interest is the DTI image to be aligned for surgical planning/reference.

Keywords

MRI, brain, head, intra-subject, DTI, T1, T2, non-rigid, tumor, surgical planning

Input Data

  • reference/fixed : T1 SPGR , 0.5x0.5x1 mm voxel size, 512 x 512 x 176
  • moving 1: T2 0.5x0.5x1.5 mm voxel size, 512 x 512 x 92
  • moving 2a: DTI baseline: 1 x 1 x 3 mm, 256 x 256 x 41
  • moving 2b: 1 x 1 x 3 mm, 256 x 256 x 41 x 9 (tensor), original: DWI 256 x 256 x 41 x 32 directions

Registration Challenges

  • The DTI sequence (EPI) contains string distortions we seek to correct via non-rigid alignment
  • the DTI baseline is similar in contrast to a T2, albeit at much lower resolution
  • we have different amounts of voxel-anisotropy

Key Strategies

  • Slicer 3.6.1 recommended modules: BrainsFit, Robust Multiresolution Affine
  • we use an 2-step approach: 1) we first co-register the T2 with the SPGR T1. 2) we register the DTI baseline to the T2 (the T1 provides insufficient similarity), 3) combine this with the Affine1 transform obtained from registering the T2 to the T1. affine transform with 12 DOF (rather than a rigid one) to address distortion differences between the two protocols; 4) resample the DTI volume with the new transform


Procedures

with BrainsFit (ca. 3 min):

  • Part I: LOAD DATA
  1. download example dataset
  2. load into 3DSlicer 3.6.1 (Load Scene)
  3. To convert the DWI into a DTI: use the Converters / DICOM to NRRD Converter module
  • Part II:REGISTER DTI TO T2
  1. open Registration : BrainsFit module
    1. Registration Phases:
    2. set T2 as fixed and DTI_baseline as moving image
    3. select/check Include Rigid registration phase
    4. select/check Include Affine registration phase
    5. select/check Include BSpline registration phase
    6. select Initialize with CenterofHeadAlign
    7. select Include Rigid registration phase
    8. select "Include Affine registration phase"
  2. Output Settings:
    1. select a new transform "Slicer BSpline Transform" under Output Transform
    2. select a new volume "Output Image Volume
  3. Registration Parameters: increase Number Of Samples to 200,000
  4. Leave all other settings at default
  5. click apply; runtime ca. 3 min.


  1. program will automatically move FLAIR image under the result transform; also manually move the labelmap
  2. right click on either image and select Harden Transform to apply & resample
  3. save result images/scene


with MultiresolutionAffine (ca. 15 min):

  1. download example dataset
  2. load into 3DSlicer 3.6
  3. open Registration : RobustAffineMultiresolution module
  4. set SPGR as fixed and FLAIR as moving image
  5. accept all defaults & click apply
  6. go to Data module and move FLAIR and labelmap under the result transform
  7. right click on either image and select Harden Transform to apply & resample
  8. save result images/scene

for more details see the tutorial under Downloads

Registration Results

Unregistered Data + segmentation labelmap unregistered

Conclusion: BrainsFit provides good registration but requires intermediate step of registering to T2.