Difference between revisions of "Projects:RegistrationLibrary:RegLib C13"
From NAMIC Wiki
Line 3: | Line 3: | ||
[[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | [[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | ||
− | + | [[Projects:ARRASuplements|Back to ARRA main page]] <br> | |
+ | [[Projects:RegistrationDocumentation|Back to Registration main page]] <br> | ||
+ | [[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | ||
− | {| style="color:#bbbbbb | + | ==<small>v3.6.3</small> [[Image:Slicer3-6Announcement-v1.png|150px]] Slicer Registration Library Case #13: Liver Tumor Cryoablation 2 == |
+ | |||
+ | === Input === | ||
+ | {| style="color:#bbbbbb; " cellpadding="10" cellspacing="0" border="0" | ||
|[[Image:RegLib_C13_LiverTumor2_CTpost.png|200px|lleft|this is the fixed reference image. All images are aligned into this space]] | |[[Image:RegLib_C13_LiverTumor2_CTpost.png|200px|lleft|this is the fixed reference image. All images are aligned into this space]] | ||
− | |[[Image: | + | |[[Image:RegArrow_NonRigid.png|100px|lleft]] |
|[[Image:RegLib_C13_LiverTumor2_CTbegin.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | |[[Image:RegLib_C13_LiverTumor2_CTbegin.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | ||
|[[Image:RegLib_C13_LiverTumor2_MRIpre_T1.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | |[[Image:RegLib_C13_LiverTumor2_MRIpre_T1.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | ||
|[[Image:RegLib_C13_LiverTumor2_MRIpre_T2.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | |[[Image:RegLib_C13_LiverTumor2_MRIpre_T2.png|200px|lleft|this is the moving image. The transform is calculated by matching this to the reference image]] | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | |fixed image/target |
| | | | ||
− | | | + | |moving image |
− | | | + | |moving image |
− | + | |moving image | |
− | + | |} | |
+ | |||
+ | |||
|0.57 x 0.57 x 5 mm<br> 512 x 512 x 37<br>RAS | |0.57 x 0.57 x 5 mm<br> 512 x 512 x 37<br>RAS | ||
| | | | ||
Line 35: | Line 39: | ||
===Input Data=== | ===Input Data=== | ||
− | * | + | *reference/fixed : 0.57 x 0.57 x 5 , 512 x 512 x 37 voxels |
− | * | + | *moving: 0.57 x 0.57 x 5 mm, 512 x 512 x 33 voxels |
+ | *moving: 1.56 x 1.56 x 2.5 mm, 256 x 256 x 88 | ||
+ | *moving: 1.56 x 1.56 x 6 mm, 256 x 256 x 36 | ||
=== Methods === | === Methods === | ||
Line 55: | Line 61: | ||
*contrast enhancement and pathology and treatment changes cause additional differences in image content | *contrast enhancement and pathology and treatment changes cause additional differences in image content | ||
*we have strongly anisotropic voxel sizes with much less through-plane resolution | *we have strongly anisotropic voxel sizes with much less through-plane resolution | ||
− | |||
− | |||
− |
Revision as of 20:47, 18 August 2011
Home < Projects:RegistrationLibrary:RegLib C13Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
v3.6.3 Slicer Registration Library Case #13: Liver Tumor Cryoablation 2
Input
fixed image/target | moving image | moving image | moving image |
|0.57 x 0.57 x 5 mm
512 x 512 x 37
RAS
|
|0.57 x 0.57 x 5 mm
512 x 512 x 33
RAS
|1.56 x 1.56 x 2.5 mm
256 x 256 x 88
RAS
|1.56 x 1.56 x 6 mm
256 x 256 x 36
RAS
|
|}
Objective / Background
We seek to align the pre-operative CT&MRI with the post-operative CT.
Keywords
MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration
Input Data
- reference/fixed : 0.57 x 0.57 x 5 , 512 x 512 x 37 voxels
- moving: 0.57 x 0.57 x 5 mm, 512 x 512 x 33 voxels
- moving: 1.56 x 1.56 x 2.5 mm, 256 x 256 x 88
- moving: 1.56 x 1.56 x 6 mm, 256 x 256 x 36
Methods
Registration Results
This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases.
Download
Discussion: Registration Challenges
- large differences in FOV
- strong differences in image contrast between MRI & CT
- contrast enhancement and pathology and treatment changes cause additional differences in image content
- we have strongly anisotropic voxel sizes with much less through-plane resolution