+ | === Procedure === | ||
+ | *'''Phase I: register CTpre - CTpost''' | ||
+ | #open the [http://wiki.slicer.org/slicerWiki/index.php/Documentation/4.1/Modules/BRAINSFit General Registration (BRAINS) module] | ||
+ | ##''Fixed Image Volume'': CTpost | ||
+ | ##''Moving Image Volume'': CTpre | ||
+ | ##Output Settings: | ||
+ | ###''Slicer BSpline Transform": create new transform, rename to "Xf1_Ctpre-CTpost_BSpline" | ||
+ | ###''Slicer Linear Transform'': none | ||
+ | ###''Output Image Volume'': create new volume, rename to "CTpre_Xf1" | ||
+ | ##''Registration Phases'': check boxes for ''Rigid'' , ''Rigid+Scale'' , ''Affine'' and "BSpline" | ||
+ | ##''Main Parameters'': | ||
+ | ###''B-Spline Grid Size'': 7,7,3 | ||
+ | ##Leave all other settings at default | ||
+ | ##click: Apply; runtime ~ 1 min (MacPro QuadCore 2.4GHz) | ||
+ | |||
=== Discussion: Registration Challenges === | === Discussion: Registration Challenges === |
Revision as of 18:50, 10 May 2012
Home < Projects:RegistrationLibrary:RegLib C13Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
v3.6.3Slicer Registration Library Case #13: Liver Tumor Cryoablation 2
Input
fixed image/target | moving image | moving image | moving image |
Objective / Background
We seek to align the pre-operative CT&MRI with the post-operative CT.
Keywords
MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration
Input Data
- reference/fixed : 0.57 x 0.57 x 5 , 512 x 512 x 37 voxels
- moving: 0.57 x 0.57 x 5 mm, 512 x 512 x 33 voxels
- moving: 1.56 x 1.56 x 2.5 mm, 256 x 256 x 88
- moving: 1.56 x 1.56 x 6 mm, 256 x 256 x 36
Registration Results
This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases. Also expected upgrades to ITK4 present in Slicer4 will likely improve performance.
Download
Procedure
- Phase I: register CTpre - CTpost
- open the General Registration (BRAINS) module
- Fixed Image Volume: CTpost
- Moving Image Volume: CTpre
- Output Settings:
- Slicer BSpline Transform": create new transform, rename to "Xf1_Ctpre-CTpost_BSpline"
- Slicer Linear Transform: none
- Output Image Volume: create new volume, rename to "CTpre_Xf1"
- Registration Phases: check boxes for Rigid , Rigid+Scale , Affine and "BSpline"
- Main Parameters:
- B-Spline Grid Size: 7,7,3
- Leave all other settings at default
- click: Apply; runtime ~ 1 min (MacPro QuadCore 2.4GHz)
Discussion: Registration Challenges
- large differences in FOV
- strong differences in image contrast between MRI & CT
- contrast enhancement and pathology and treatment changes cause additional differences in image content
- we have strongly anisotropic voxel sizes with much less through-plane resolution