Difference between revisions of "Projects:RegistrationLibrary:RegLib C06"
From NAMIC Wiki
Line 13: | Line 13: | ||
[[Image:Button_green_moving.jpg|20px|lleft]] this indicates the moving image that determines the registration transform. <br> | [[Image:Button_green_moving.jpg|20px|lleft]] this indicates the moving image that determines the registration transform. <br> | ||
|- | |- | ||
− | |[[Image:Button_red_fixed.jpg|40px|lleft]] | + | |[[Image:Button_red_fixed.jpg|40px|lleft]] axial |
| | | | ||
|[[Image:Button_green_moving.jpg|40px|lleft]] T1 SPGR | |[[Image:Button_green_moving.jpg|40px|lleft]] T1 SPGR | ||
|- | |- | ||
− | |0. | + | |0.44 x 0.44 x 5 mm<br> 784 x 784 x 30<br>RAS |
| | | | ||
− | |0. | + | |0.68 x 0.68 x 1.5 mm<br> 515 x 515 x 93<br>RAS |
|} | |} | ||
===Objective / Background === | ===Objective / Background === | ||
Line 47: | Line 47: | ||
*contrast enhancement and pathology and treatment changes cause additional differences in image content | *contrast enhancement and pathology and treatment changes cause additional differences in image content | ||
*the surface coils used cause strong differences in intensity inhomogeneity. | *the surface coils used cause strong differences in intensity inhomogeneity. | ||
+ | *we have strongly anisotropic voxel sizes with much less through-plane resolution | ||
*resolution and FOV change between the two scans | *resolution and FOV change between the two scans | ||
Revision as of 15:58, 23 February 2010
Home < Projects:RegistrationLibrary:RegLib C06Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
Slicer Registration Use Case Exampe #6: Breast MRI Treatment Assessment
Objective / Background
We seek to align the post-treatment (PostRx) scan with the pre-treatment scan to compare local effects.
Keywords
MRI, breast cancer, intra-subject, treatment assessment, change detection, non-rigid registration
Input Data
- reference/fixed : T1 SPGR , 0.9375 x 0.9375 x 1.4 mm voxel size, axial, RAS orientation.
- moving: T1 SPGR , 0.9375 x 0.9375 x 1.2 mm voxel size, sagittal, RAS orientation.
Registration Results
Download
Link to User Guide: How to Load/Save Registration Parameter Presets
Discussion: Registration Challenges
- soft tissue deformations during image acquisition cause large differences in appearance
- contrast enhancement and pathology and treatment changes cause additional differences in image content
- the surface coils used cause strong differences in intensity inhomogeneity.
- we have strongly anisotropic voxel sizes with much less through-plane resolution
- resolution and FOV change between the two scans
Discussion: Key Strategies
- because of the strong changes in shape and position, we break the problem down and register each breast separately.
- we perform a bias-field correction on both images before registration
- we use the Multires version of RegisterImages for an initial affine alignment
- the nonlinear portion is then addressed with a BSpline or DiffeomorphicDemons algorithm
- because accuracy is more important than speed here, we increase the sampling rate (i.e. the number of points sampled for the BSpline registration)