Difference between revisions of "Projects:RegistrationLibrary:RegLib C14"
From NAMIC Wiki
Line 56: | Line 56: | ||
*we use the Volumes module to adjust the MRI voxel size based on the info in the DICOM header | *we use the Volumes module to adjust the MRI voxel size based on the info in the DICOM header | ||
*we use the Transforms module to reorient the MRI along the proper axes | *we use the Transforms module to reorient the MRI along the proper axes | ||
− | *Register Images is used to automatically align the PET with the MRI | + | **the aspect ratio we correct via the "Volumes" module. The correct slice thickness we obtain from the DICOM header via the browser displayed when selecting "Add Volume" |
+ | **the "Transforms" module is used to correct orientation. We enter manual rotations of 90 and 180 degrees around the LR (left-right) and IS (inferior-superior) axes, respectively | ||
+ | **the corrected MRI volume is resampled in the Data module via "harden transforms" | ||
+ | *Register Images is used to automatically align the PET with the MRI. We choose mutual information ("MI") as the criterion and a 5% sampling rate. We request an affine transform to correct for small distortion differences between the PET and the MRI |
Revision as of 15:47, 30 March 2010
Home < Projects:RegistrationLibrary:RegLib C14Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
Slicer Registration Use Case Exampe #14: Intra-subject Brain PET-MRI with MRI orientation adjustment
Objective / Background
Image fusion.
Keywords
PET-MRI, brain, intra-subject, image fusion
Input Data
- reference/fixed : baseline MRI: 0.97 x 0.97 x 3.27 mm , PET: 4.7 x 4.7 x 3.3 mm
- moving: PET: 4.1 x 4.1 x 5 mm
Registration Results
Download
- download full tutorial set (Data+intermediate results+presets+tutorial, zip file 17 MB)
- download example data set (Data only, zip file 16 MB)
- download step-by-step tutorial (PowerPoint 1.2 MB)
Link to User Guide: How to Load/Save Registration Parameter Presets
Discussion: Registration Challenges
- the original DICOM files of the MRI have image orientation data stripped. Hence the volume does not load in correct orientation and needs to be adjusted
- the two series have different voxel sizes
- image content and resolution in PET is low
Discussion: Key Strategies
- we use the Volumes module to adjust the MRI voxel size based on the info in the DICOM header
- we use the Transforms module to reorient the MRI along the proper axes
- the aspect ratio we correct via the "Volumes" module. The correct slice thickness we obtain from the DICOM header via the browser displayed when selecting "Add Volume"
- the "Transforms" module is used to correct orientation. We enter manual rotations of 90 and 180 degrees around the LR (left-right) and IS (inferior-superior) axes, respectively
- the corrected MRI volume is resampled in the Data module via "harden transforms"
- Register Images is used to automatically align the PET with the MRI. We choose mutual information ("MI") as the criterion and a 5% sampling rate. We request an affine transform to correct for small distortion differences between the PET and the MRI