Difference between revisions of "Projects:RegistrationLibrary:RegLib C13"
From NAMIC Wiki
Line 3: | Line 3: | ||
[[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | [[Projects:RegistrationDocumentation:UseCaseInventory|Back to Registration Use-case Inventory]] <br> | ||
− | ==<small>v3.6.3</small> [[Image: | + | ==<small>v3.6.3</small>[[Image:UnderConstruction_xparent.png|60px| these cases are not yet registered / under development]]Slicer Registration Library Case #13: Liver Tumor Cryoablation 2 == |
=== Input === | === Input === | ||
Line 33: | Line 33: | ||
=== Registration Results=== | === Registration Results=== | ||
− | This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases. | + | This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases. Also expected upgrades to ITK4 present in Slicer4 will likely improve performance. |
===Download === | ===Download === |
Revision as of 14:52, 29 August 2011
Home < Projects:RegistrationLibrary:RegLib C13Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
v3.6.3Slicer Registration Library Case #13: Liver Tumor Cryoablation 2
Input
fixed image/target | moving image | moving image | moving image |
Objective / Background
We seek to align the pre-operative CT&MRI with the post-operative CT.
Keywords
MRI, CT, IGT, intra-operative, liver, cryoablation, change detection, non-rigid registration
Input Data
- reference/fixed : 0.57 x 0.57 x 5 , 512 x 512 x 37 voxels
- moving: 0.57 x 0.57 x 5 mm, 512 x 512 x 33 voxels
- moving: 1.56 x 1.56 x 2.5 mm, 256 x 256 x 88
- moving: 1.56 x 1.56 x 6 mm, 256 x 256 x 36
Registration Results
This case is currently unsolved with standard Slicer 3.6 technology. Special/custom modifications to registration modules (SlicerIGT Registration) are under way and will be incorporated into future releases. Also expected upgrades to ITK4 present in Slicer4 will likely improve performance.
Download
Discussion: Registration Challenges
- large differences in FOV
- strong differences in image contrast between MRI & CT
- contrast enhancement and pathology and treatment changes cause additional differences in image content
- we have strongly anisotropic voxel sizes with much less through-plane resolution