Data:DBP2:Harvard

From NAMIC Wiki
Revision as of 13:57, 17 September 2008 by Dougt (talk | contribs)
Jump to: navigation, search
Home < Data:DBP2:Harvard
Back to Harvard DBP 2, DBP 2 Data

Harvard Data

Data Access

To download this data, click on the following links: >> DATA IS NOT YET AVAILABLE ON BIRN (9/8/08).

  • Ensure you are logged into the portal portal
  • Download all data 3T Data
    • Here is the pathway in BIRN once you're logged in: /home/Projects/NAMIC__0003/Files/PNL/3T_strct_dti_fmri
    • In each of the 20 case files, you will find ten files.

Data Description

  • Structural MRI (sMRI) For the Structural MRI volume measurements, images will be acquired using a 3T GE) at BWH in Boston, MA. We will use an 8 Channel coil in order to perform parallel imaging using ASSET (Array Spatial Sensitivity Encoding techniques, GE) with a SENSE-factor (speed-up) of 2. The structural MRI acquisition protocol will include two MRI pulse sequences. The first results in contiguous spoiled gradient-recalled acquisition (fastSPGR) with the following parameters; TR=7.4ms, TE=3ms, TI=600, 10 degree flip angle, 25.6cm^2 field of view, matrix=256x256. The voxel dimensions are 1x1x1 mm. The second- XETA (eXtended Echo Train Acquisition) produces a series of contiguous T2-weighted images (TR=2500ms, TE=80ms, 25.6 cm^2 field of view, 1 mm slice thickness). Voxel dimensions are 1x1x1 mm.
  • Diffusion Tensor Imaging (DTI) DTI scans will be acquired on a 3 Tesla GE system using an echo planar imaging (EPI) DTI Tensor sequence. We will use a double echo option to reduce eddy-current related distortions (Heid 2000; Alexander 1997). To reduce impact of EPI spatial distortion, we will use an 8 Channel coil that will allow us to perform parallel imaging using ASSET (Array Spatial Sensitivity Encoding Techniques, GE) with a SENSE-factor (speed-up) of 2. We will acquire 51 directions with b=*9*00, 8 baseline scans with b=0. The following scan parameters will be used: TR 17000 ms, TE 78 ms, FOV 24 cm, 144x144 encoding steps, 1.7 mm slice thickness. We will acquire 85 axial slices parallel to the AC-PC line covering the whole brain. In addition, Bo field inhomogeneity maps will be collected.
  • Resting State fMRI This sequence is an additional EPI BOLD sequence that requires Brain Wave software, available only with 8 Channel coil. It's a resting state fMRI that was 10 minutes long, and contains 200 repetitions of a high resolution EPI scan (96x96 in plane, 3mm thickness, TR-3000 ms, TE=30, 39 slices, ASSETT). Subjects closed their eyes and rested while the magnet is running.

Data Contact

If you have any questions about the data, please contact Sylvain Bouix (sylvain@bwh.harvard.edu) or Doug Terry (dougt@bwh.harvard.edu) at Harvard.