Projects:RegistrationLibrary:RegLib C37
From NAMIC Wiki
Home < Projects:RegistrationLibrary:RegLib C37
v3.6.1 Slicer Registration Library Case #37:
Back to ARRA main page
Back to Registration main page
Back to Registration Case Library
Contents
v3.6.1 Slicer Registration Library Case #37:
Intra-subject Brain MRI: T1 Tumor Growth / Resection Assessment
Input
fixed image/target | moving image |
Modules
Slicer 3.6.1 recommended modules:
Objective / Background
This is a typical case of change assessment.
Keywords
MRI, brain, head, intra-subject, T1, tumor, change assessment
Input Data
- reference/fixed : T1 SPGR , 1x1x1 mm voxel size, 256x256x176 ,sagittal
- moving: T1 SPGR , 1x1x1 mm voxel size, 256x256x176 ,sagittal
Overall Strategy
- run rigid/affine registration (BRAINSfit) with "CenterOfHeadAlign" initialization
- run 7x7x7 nonrigid regista=ration (BRAINSfit BSpline) using the above affine as input
- alternative: run skull stripper module on both images to generate masks for the nonrigid registration
Procedures
- Phase I: Register Rigid/Affine
- open Registration : BrainsFit module (presets: BRAINSfit_Xf1 or _Xf2
- Registration Phases:
- select/check Include Affine registration phase
- for affine also select/check Include Scale Versor 3D and Include Affine registration phase
- Registration Parameters: increase Number Of Samples to 200,000
- select a new transform "Linear Transform", rename to "Xf1_affine"
- Leave all other settings at default
- Registration Phases:
- Phase I: Register BSpline
- select a new volume "Output Image Volume, rename to "DTI_base_Xf1"
- Registration Parameters: increase Number Of Samples to 200,000
- Registration Parameters: set Number Of Grid Subdivisions to 7x7x7
- Leave all other settings at default
Registration Results
original unregistered | |
rigid registered | affine registered |
nonrigid registered (7x7x7 BSpline unmasked) | nonrigid registered (7x7x7 BSpline masked) |
Download
- Data
- Presets