Difference between revisions of "Projects:RegistrationLibrary:RegLib C35"
From NAMIC Wiki
Line 16: | Line 16: | ||
=== Modules === | === Modules === | ||
− | *'''Slicer 3.6.1 recommended modules:''' [http://www.slicer.org/slicerWiki/index.php/Modules: | + | *'''Slicer 3.6.1 recommended modules:''' [http://www.slicer.org/slicerWiki/index.php/Modules:PythonSurfaceICPRegistration-Documentation-3.6 '''SurfaceRegistration'''], [http://www.slicer.org/slicerWiki/index.php/Modules:Transforms '''Transforms (manual registration)'''], [http://www.slicer.org/slicerWiki/index.php/Modules:FastMarchingSegmentation-Documentation-3.6 '''Fast Marching Segmentation'''], [http://www.slicer.org/slicerWiki/index.php/Modules:HistogramMatching-Documentation-3.6 '''Histogram Matching'''], [http://www.slicer.org/slicerWiki/index.php/Modules:ModelMaker-Documentation-3.6 '''Model Maker'''], |
===Objective / Background === | ===Objective / Background === |
Revision as of 18:28, 1 March 2011
Home < Projects:RegistrationLibrary:RegLib C35Back to ARRA main page
Back to Registration main page
Back to Registration Use-case Inventory
Contents
v3.6.1 Slicer Registration Library Case #35: Mouse Colon Brain MRI
Input
fixed image 1/target MRI mouse 1 |
moving image MRI mouse 2 |
Modules
- Slicer 3.6.1 recommended modules: SurfaceRegistration, Transforms (manual registration), Fast Marching Segmentation, Histogram Matching, Model Maker,
Objective / Background
Aim is to register the two MRIs such that the colon aligns.
Download
Keywords
MRI, colon, mouse, masking, non-human, non-rigid,manual, unsolved
Input Data
- reference/fixed MRI: 0.12 x 0.12 x 0.1 mm, 512 x 512 x 94
- moving MRI: 0.09 x 0.09 x 0.1 mm, 512 x 512 x 94
Registration Challenges
- The image content to be registered is less than 10% of the total image and of low energy (close to background);
- there's large portions of the colon for which no matching/corresponding structures exist, i.e. a straightforward one-one mapping is not avail.
- other landmarks (kidneys etc.) are very different in position and size
Key Strategies
- This is a challenge case and currently unsolved. Best hopes are combinations of manual, fiducial and surface-based registration
- Slicer 3.6.1 recommended modules:
Registration Results
very rough surface models of colon help visualize misalignment
original, not registered
after surface registration (rigid) + manual correction